EasyManua.ls Logo

Gree U-Match 6 Series - Page 27

Gree U-Match 6 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GREE U-Match 6 SERIES UNIT SERVICE MANUAL
24
2.3.13.3 Selecting door control function
Under debugging state, press “
” or “
” button to select parameter code to “02” in temperature
displaying zone. Timer zone displays setting state and press “
” or “
” button to adjust. There are 2
selections:
(1) Without door control function (LCD displays 00).
(2) With door control function (LCD displays 01).
Press “ENTERbutton to finish setting.
2.3.13.4 Displaying setting of freeze protection error code
Under debugging state, press “
” or “
” button to select parameter code to “03” in temperature
displaying zone. Timer zone displays setting state and press “
” or “
” button to adjust. There are 2
selections:
(1) Displayed (LCD displays 00).
(2) Not Displayed (LCD displays 01).
Press “ENTERbutton to finish setting.
2.3.13.5 Defrost mode selection
Under debugging state, press “
” or “
” button to select parameter code to “06” in temperature
displaying zone. Timer zone displays setting state and press “
” or “
” button to adjust. There are 2
selections:
(1) Defrost mode 1 (LCD displays 00).
(2) Defrost mode 2 (LCD displays 01).
Press “ENTERbutton to finish setting.
2.3.13.6 Heat pump unit and cooling only unit selection
Under debugging state, press “
” or “
” button to select parameter code to “07” in temperature
displaying zone. Timer zone displays setting state and press “
” or “
” button to adjust. There are 2
selections:
(1) Heat pump type unit (LCD displays 00).
(2) Cooling only unit (LCD displays 01).
Press “ENTERbutton to finish setting.
2.3.13.7 Selecting blowing residual heating of indoor unit
Under debugging state, press “
” or “
” button to select parameter code to “08” in temperature

Related product manuals