Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property damage!
1
Upblast Centrifugal Roof Exhaust Fans
General Safety Information
Only qualified personnel should install this fan.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards.
Other considerations may be required if high winds
or seismic activity are present. If more information is
needed, contact a licensed professional engineer before
moving forward.
1. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the National
Fire Protection Agency (NFPA), where applicable.
Follow the Canadian Electrical Code (CEC) in
Canada.
2. The rotation of the wheel is critical. It must be
free to rotate without striking or rubbing any
stationary objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than max cataloged fan
RPM. Adjustments to fan speed significantly effects
motor load. If the fan RPM is changed, the motor
current should be checked to make sure it is not
exceeding the motor nameplate amps.
5. Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
6. Verify that the power source is compatible with
the equipment.
7. Never open access doors to a duct while the fan
is running.
Model CUE
Direct Drive
Model CUE is a direct drive upblast
centrifugal exhaust fan. These fans
are specifically designed for roof
mounted application. Performance
capabilities range up to 6,400
cfm (10,874 m
3
/hr) and up to
3 in. wg (747 Pa) of static pressure.
The maximum continuous operating
temperature for fan sizes 098-200 is
400°F (204°C) and for fan sizes 060-
095 is 160°F (71°C). CUE fans are
available in fourteen sizes with nominal wheel diameter
ranging from 9 to 20 inches (229to 508 mm) (060 - 200
unit sizes). Each fan shall bear a permanently affixed
manufacturers engraved metal nameplate containing the
model number and individual serial number.
Model CUBE
Belt Drive
Model CUBE is a belt drive upblast
centrifugal exhaust fan. These fans
are specifically designed for roof
mounted applications. Performance
capabilities range up to 30,000 cfm
(50,970 m
3
/hr) and up to 5.0 in. wg
(1240 Pa) of static pressure. The
maximum continuous operating tem-
perature is 400°F (204°C). CUBE fans
are available in fourteen sizes with
nominal wheel diameter ranging from
9 to 48 inches (229 to 1219 mm) (098 - 480 unit sizes).
Each fan shall bear a permanently affixed manufacturers
engraved metal nameplate containing the model num-
ber and individual serial number.
DANGER
Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
CAUTION
Precaution should be taken in explosive atmospheres.
®
®
Document 471560
Upblast Centrifugal Roof Exhaust Fans
Question and Answer IconNeed help?

Do you have a question about the Greenheck CUE Series and is the answer not in the manual?

Greenheck CUE Series Specifications

General IconGeneral
Drive TypeDirect Drive
Housing MaterialGalvanized steel
Wheel TypeBackward inclined
TypeCentrifugal
ApplicationCommercial, Industrial
MotorTEFC
OptionsDisconnect switch, motor speed control, roof curb

Summary

Product Overview and Safety

Model CUE Direct Drive

Details of the direct drive upblast centrifugal exhaust fan, including performance capabilities.

Model CUBE Belt Drive

Details of the belt drive upblast centrifugal exhaust fan, including performance capabilities.

General Safety Information

Critical safety precautions and warnings for installation, operation, and maintenance.

Receiving, Handling, and Storage

Receiving and Unpacking

Procedures for checking the bill of lading and inspecting units for shipping damage.

Handling and Lifting

Guidelines for safely lifting and moving CUE and CUBE fan units using appropriate equipment.

Storage Guidelines

Recommendations for storing units indoors and outdoors to prevent damage and deterioration.

Installation Procedures

Typical Roof Mounting Installation

Step-by-step instructions for mounting the fan securely on a roof curb.

Electrical Connection Procedures

Instructions for connecting power supply wiring to the fan motor, ensuring compatibility.

Specialized Installation Guidance

Specific requirements for kitchen and general ventilation installations.

Specific Systems and Components

Emergency Smoke Control

Requirements and installation procedures for emergency smoke removal applications.

Grease Trap System

Installation, maintenance, and function of the grease trap component.

Pre-Operation and Maintenance

Pre-Starting Checks

Essential checks for fasteners, wheel, and belts before operating the fan.

CUBE Belt Drive Adjustments

Procedures for adjusting belt tension and alignment on CUBE units.

Fan Operation Guidelines

How to start, operate, and monitor the fan for performance and safety.

Inspection and Maintenance

Recommended inspection intervals and maintenance tasks for ensuring longevity.

Belt and Bearing Maintenance (CUBE)

Specific maintenance procedures for belts and bearings on CUBE units.

Related product manuals