Transmitter (2012-T)
The transmitter and receiver combination is capable of tracing standard
U.S. household wiring for at least 300 feet. Actual trace distance will
vary depending on wire resistance and the material of the wall, ceiling or
floor being traced through.
Voltage Range: 100 to 125 V, 50 to 60 Hz
Wattage: 1 W
Operating Temperature: 10 °C to 40 °C (14 °F to 104 °F)
Storage Temperature: 10 °C to 55 °C (14 °F to 131 °F)
Relative Humidity: 0% to 80% (non-condensing)
Altitude: 2000 m (6500') maximum
Overvoltage Category: Category III, 150 Volts
Indoor use only
Receiver (2012-R)
Operating Temperature: 10 °C to 40 °C (14 °F to 104 °F)
Storage Temperature: 10 °C to 55 °C (14 °F to 131 °F)
Remove battery.
Battery: 9-Volt (NEDA 1604, JIS 006P or IEC 6F22)
Low Battery Indication: Low. Bat. LED illuminates
Overvoltage Category: Category III, 150 Volts
Indoor use only. Not intended for contact with live circuits.