Do you have a question about the Greyline AVFM 6.1 and is the answer not in the manual?
Type | Area-Velocity Flow Meter |
---|---|
Enclosure Rating | IP68 |
Operating Frequency | 1 MHz |
Sensor Material | Stainless Steel |
Output | 4-20 mA |
Operating Temperature | -40 to 60 °C |
Channels | Single channel |
Measurement Principle | Doppler Ultrasonic |
Visual representation of electrical terminal connections for the AVFM 6.1.
Verifies sensor and meter operation after power application.
Details the device's menu navigation and button functions.
Explains main display, message icon, and status indicators.
Visual indicators and their meanings displayed on the meter screen.
Overview of the menu structure for instrument calibration and configuration.
Setting measurement units and operating modes like Flow or Velocity.
Inputting pipe or channel dimensions for accurate flow calculations.
Setting measurement limits and analog output levels for level.
Configuring analog outputs and zero points for velocity and flow.
Adjusting signal cutoff, damping, LOE time, and calibration constant.
Configuring data logging interval, format, and site ID.
Setting up serial communication parameters and wiring for MODBUS.
Register addresses and data formats for MODBUS communication.
Accessing advanced features like language, backlight, and restore defaults.
Testing outputs and relays by simulating input values.
Optimal placement of the sensor relative to flow disturbances.
Installation criteria for dams, weirs, and channel grade.
Minimizing upstream/downstream disturbances affecting flow measurement accuracy.
Instructions for installing the QZ02L velocity-level sensor.
Methods for mounting optional pipe band and velocity sensors.
Installing the PZ15-LP ultrasonic level sensor.
Guidelines for mounting and wiring the instrument enclosure.
Procedures for cleaning the QZ02L sensor in dirty water.
Details on optional heater, thermostat, and sunscreen for the enclosure.
Diagnosing and resolving problems with level readings.
Diagnosing and resolving problems with velocity readings.
Testing sensor cable integrity using a multimeter.
Contact information for support and steps for returning instruments.
Terms and conditions of the manufacturer's warranty.
Details on optional components like extra sensor cables and junction boxes.
CSA certifications for hazardous location installations.
Technical details of intrinsic safety barriers.
Connecting and configuring the 9-32VDC power input.
Comprehensive technical data and operating parameters for the AVFM 6.1.
Detailed technical specifications for the QZ02L velocity-level sensor.
Specifications for optional QZ02L-B and PZ15-LP sensors.
Wiring diagram for connecting dual sensors to the AVFM 6.1.
Methods for mounting PZxx sensors using flange adapters.
Procedures for sensor coupling and mounting the SE4 sensor.