EasyManua.ls Logo

GRIGGIO G 240 P4 - User Manual

GRIGGIO G 240 P4
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
G 240 4/5/6/7
G 240 4/5/6/7G 240 4/5/6/7
G 240 4/5/6/7
MOULDER
MOULDERMOULDER
MOULDER
Code Language
3650142 004 GB
_________________________________________________________________________________________________________________
INSTRUCTIONS
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONS
10
1010
10/0
/0/0
/09
99
9
SPARE PARTS
SPARE PARTSSPARE PARTS
SPARE PARTS
GRIGGIO
GRIGGIOGRIGGIO
GRIGGIO
WOODWORKING MACHINERY
WOODWORKING MACHINERYWOODWORKING MACHINERY
WOODWORKING MACHINERY
Via Ca' Brion, 40 – 35011 Reschigliano (PD) ITALY
Tel. ++39 049 9299711 Fax ++39 049 9201433
http://www.griggio.com
E-mail:info@griggio.com

Table of Contents

Questions and Answers

  • K
    Kristi JohnsonAug 7, 2025
    What to do if the display shows numbers, but they don't change with the motor on my GRIGGIO G 240 P4 Industrial Equipment?
    • D
      Darryl ShannonAug 7, 2025
      If the display shows numbers, but they don't change when the bottom/top motor runs, first, ensure the proximity switch indicators light up when the table indexes. If not, replace the switch. Next, ensure the sensor and disc are less than 1 mm apart, adjusting if needed. If an ENCODER is used, check its function during table indexing, replacing it if disassembled or damaged. Lastly, verify the A B phase complies with the 12 VDC encoder signal; replace the ENCODER if there are no changes in the A B phases.
  • S
    Sarah PageAug 15, 2025
    Why does the display show the numbers in an irregular fashion on my GRIGGIO G 240 P4 Industrial Equipment?
    • B
      Benjamin JordanAug 15, 2025
      If the display on your GRIGGIO Industrial Equipment shows numbers irregularly, first, ensure the dimensions on the programmer match the actual dimensions. If the issue persists, check and correct the parameters. After these steps, turn the power off and on again. If the display remains irregular, the programmer should be sent to the supplier for repair.
  • S
    Stephanie StoutAug 21, 2025
    How to fix a GRIGGIO Industrial Equipment display that does not show numbers?
    • B
      brownjoshuaAug 21, 2025
      If the display on your GRIGGIO Industrial Equipment isn't showing any numbers, check that the electrical power supply voltage (220V or 110V AC) is normal and reconnect the correct voltage if necessary. Also, verify that the fuse hasn't blown; if it has, replace it with a new 1A fuse. If both are normal, the control circuit may be faulty and should be sent to the supplier for repair.
  • V
    Victoria BarrettAug 29, 2025
    What to do if my GRIGGIO Industrial Equipment displays incorrect values?
    • J
      Jason WilliamsAug 29, 2025
      If your GRIGGIO Industrial Equipment displays incorrect values, check the data reset of the programmer and the encoder's resolution. If the programmer's parameter does not conform to the table, correct the parameter.

Summary

Skilled Personnel

Technical Data

Technical Features G 240 P4

Detailed specifications for the G 240 P4 model.

Technical Features G 240 P5

Detailed specifications for the G 240 P5 model.

Technical Features G 240 P5 U

Detailed specifications for the G 240 P5U model.

Technical Features G 240 P6

Detailed specifications for the G 240 P6 model.

Technical Features G 240 P 6 U

Detailed specifications for the G 240 P 6U model.

Technical Features G 240 P 7 U

Detailed specifications for the G 240 P 7U model.

Electrical Connection

Pneumatic Feed

Suction

Noise Production Values

Dust Production

Operating Instructions

Operators Training

Requirements for operator qualification and training.

Safety Warnings

Tool Assembly

Preplaner Table and Infeed Fence

General Adjustment of the Mechanical Digital Indicator

First Lower Planer Shaft Adjustment

Right-Hand Vertical Planer Shaft Adjustment (Second Shaft)

Left-Hand Vertical Planer Shaft Adjustment (Third Shaft)

Upper Horizontal Planer Shaft Adjustment (Fourth Shaft)

Second Lower Planer Shaft Adjustment

Universal Shaft Adjustment

Lower Roller Undertable Adjustment

Feeding Device Adjustment

Cleaning and Lubricating.

Belt Tensioning and Replacement

Machine Starting and Stopping

Feeding by Inverter

Electronic Display Model TC-501 B

25.1. Specifications

Technical details of the TC-501B display unit.

25.2. Features

Key functionalities and capabilities of the TC-501B display.

25.3. Main Panel Illumination

Explanation of the indicators and display elements on the main panel.

25.4. Manipulation Procedure

Instructions on how to operate and set the TC-501B display unit.

25.5. Connection Sketch Map

Diagram illustrating the back panel connections for the TC-501B.

25.6. Reference Table for Parameters Setting

Guide for setting operational parameters on the TC-501B display.

25.7. Maximal Exterior Size and Installing Size

Physical dimensions and mounting hole specifications for the TC-501B.

Troubleshooting

Problem - Probable Cause - Cure

27.1. Problems with the Cutter

Specific issues and solutions related to cutting tools.

Electric Problems

List of Normally Replaced Standard Components

28.1. Bearing List

An inventory of bearings used within the machine's assemblies.

GRIGGIO G 240 P4 Specifications

General IconGeneral
BrandGRIGGIO
ModelG 240 P4
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals