EasyManua.ls Logo

GroTech TEC 4 NG - Setting Daily Dosing Quantity; Setting Dosing Frequency; Setting Pump Start Time; Setting Dosing Days

GroTech TEC 4 NG
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Now please choose group 1-4 and confirm this with key
and the sub-menue is entered:
SETUP
Pump 1
By pressing the arrow key or you can now choose the pumps 1,2,3 or 4 to be adjusted.
By pressing the key
the sub-menue is entered for programming of pump 1.
ml/DAY
P1: 0000
Now the cursor is positioned underneath the 1. digit. Here you can change with the aid of arrow key
or the first digit of the dosing quantity (1000 oder 0000).
By pressing the key
the cursor is positioned under the 2. digit, that means 0000.
Here the 2. digit can be changed (0-9).
Please repeat this procedure for the 3. and 4. digit. Thus you can set between 1 and 1999 ml/day.
By pressing the key
the value for the daily dosing quantity is set and the menue dosing frequency is
entered. That means here you can set in how many portions the dosing quantity adjusted before shall
be divided. Only the settings 1, 2, 3, 4, 6, 8,12 or 24 are possible.
CYCL/DAY
P1: 1
Press the arrow key
or
that often till the requested dosing frequency, i.e. 12.
That means in case of 24 ml dosing quantity and 12 cycles, the dosing quantity of 24 ml will be split
into 12 portions à 2 ml each.
These 2 ml will be dosed into the aquarium every 2 hours resp. in case of another number of cycles
equally be split on 24 h.
Standardized the value 1 is indicated in case of dosing quantities below 160 ml/day, with larger
dosing quantities the dosing frequency is increased automatically, so that the dosing quantity
of 160 ml per cycle will not be exceeded.
On the other hand, the number of cycles can only be increased that much, that a minimum dosing
quantity of 0,5 ml per cycle is not fallen below.
By pressing again key
the value of the cycles is set and the menue point is entered
Start:
00:00
Here the starting time of pump 1 can be set by pressing arrow key
or
In case of the pumps the starting minutes are fix and only the starting hour can be changed.
The individual pumps have a preset time increment of 5 minutes, which cannot be influenced.
i.e. 1 14:00; pump 2 15:05; pump 3 18:10; pumpe 4 13:15 etc.
By pressing again key
the start time is stored and the programm moves into the day programming.
MTWTFSS
1 1 1 1 1 1 1
Here the dosing day of pump 1 can be set by pressing arrow key
or
.
The upper row on the display shows the week days (M=Monday / T=Tuesday / W=Wednesday a.s.o.).
The lower row on the display shows if it is dosed at this day. (1 stands for YES / 0 stands for NO)
Example:
MTWTFSS
1 0 1 1 1 0 1
Tuesday + Saturday is not dosed.
By pressing key
programming of the pump is closed and you will enter again the setup menue.
The display now indicates
Setup
Pump 1
Now by pressing the arrow key
or
the other pumps to be programmed can be chosen or by pressing
key
the just set values can be stored and the sub-menue can be left.
The set and stored values will be maintained also in case of a longer interruption of the mains supply.
Calibrating:
By the calibrating operation the individual pumps can be improved in their dosing accuracy. Prepare an appropriate
measuring cup (25 ml) and deaerate the pumps which shall be calibrated. (see Manual control of the pumps).
By pressing the key
you move into the main menu.
Press the arrow key
or
that often until you reach the sub menu
CALI-
BRATION
Pressing the key
to enter the sub menu.
The display indicates now: