15
16
·
· Don't put any things on the inverter. Do not cover the inverter.
· Do not install the inverter near television antenna or any other antennas and
antenna cables.
· Inverter requires adequate cooling space. Providing better ventilation for the
inverter to ensure the heat escape adequately. The ambient temperature should
be below 40°C to ensure optimum operation.
· Do not expose the inverter to direct sunlight, as this can cause excessive
heating and thus power reduction.
· Observe the Min. clearances to walls, other inverters, or objects as shown in
the diagram:
Be sure that the inverter is out of the children's reach.
Direction
above
below
sides
front
Min. clearance (cm)
30
50
30
30
Ambient dimensions of one inverter
Ambient dimensions of a series inverters
Min.30cm
Min.50cm
Min.30cm
Min.30cm
Min.30cm
Min.30cm
Min.50cm
Min.50cm
Min.50cm
Min.50cm
Min.50cm
Min.50cm
Min.50c
m
Min.50cm
Min.50cm
Min.50cm
Min.30cm
Min.30cm
Min.30cm
Min.30cm