EasyManua.ls Logo

Growatt MIN 3800TL-XH-US User Manual

Growatt MIN 3800TL-XH-US
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GR-UM-210-A-00GR-UM-210-A-00
Installation
Operation Manual
&
Download
Manual
Growatt New Energy
Growatt USA,Inc
9227 Reseda Blvd,#435 Northridge,CA 91324,USA.
+818 800-9177
www.growatt-america.com
T
E usaservice@ginverter.com
W
Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 3800TL-XH-US and is the answer not in the manual?

Growatt MIN 3800TL-XH-US Specifications

General IconGeneral
ModelMIN 3800TL-XH-US
Rated Power3800 W
Max. DC Input Voltage600 V
Nominal DC Voltage360 V
Number of MPPT2
Max DC Input Current13 A
Max. Input Current per MPPT13 A
Max. Short Circuit Current per MPPT15 A
Max. AC Power3800 W
Max. AC Output Power3800 W
Output Voltage240 V
Nominal AC Voltage240 V
Nominal Grid Frequency60 Hz
AC Frequency60 Hz
THDi< 3%
CEC Weighted Efficiency97.5%
DC SwitchYes
Protection DegreeIP65
CoolingNatural Cooling
Cooling MethodNatural Cooling
Weight12.5kg
Input Voltage Range90V-550V
AC Voltage Range184 V - 264 V
Power Factor Adjustment Range0.8 leading - 0.8 lagging
Operating Temperature Range-25°C to 60°C
CommunicationWiFi, Ethernet, RS485

Summary

Safety and Intended Use

General Safety Instructions

Critical guidelines to prevent injury and equipment damage during operation.

Operational Safety Warnings

General Operation Warnings

Alerts users to potential hazards during the inverter's operation.

Inverter Product Details

Installation Guidance

Installation Safety Instructions

Safety precautions specifically for the installation process.

Installation Location Selection

Guidance on choosing an appropriate and safe place for inverter installation.

Inverter Mounting Instructions

Electrical Connection Safety

Electrical Safety

Critical safety measures for electrical wiring and connections.

Electrical Connection Procedures

AC Connection Requirements

AC Circuit Breaker Requirements

Specifies the necessary AC breaker types and ratings for safe disconnection.

DC and Communication Ports

Grounding

Guidelines for proper grounding of the inverter and system components.

AC Output Connection Guide

AC Grid Connection

Steps for connecting the AC output power cable to the grid.

Battery Connection Guide

Battery Power Cable

Instructions for connecting the power cables between the inverter and battery.

Communication Connection Setup

LAN Communication Setup

System Commissioning

Pre-Power-On Checks

Checklist for verifying correct installation before initial power-up.

Powering on the System

Step-by-step guide for energizing the inverter and connected systems.

Operation and Shutdown Procedures

Powering Off the System

Procedure for safely shutting down the inverter and its connected power sources.

Shinephone App Usage

Shinephone App Connectivity

Connect to Inverter Wi-Fi

Steps to establish a Wi-Fi connection between the mobile phone and the inverter.

Troubleshooting and Faults

Troubleshooting Guide

Solutions for common inverter operational issues and error messages.

Error and Fault Resolution

System Faults

Analysis and resolution for system-level faults not directly caused by the inverter.

Inverter Faults and Warnings

Codes and descriptions for inverter-specific faults and warnings.

Growatt Warranty

Technical Specifications

PV Input Specifications

Detailed technical parameters for PV input voltage, current, and power.

Battery Specifications

Technical details regarding battery voltage, current, power, and technology.

Technical Output and Interfaces

AC Output Data

Specifications for AC nominal power, apparent power, and voltage.

Inverter Efficiency Curve

Ambient Temperature Effects

Temperature Derating

How ambient temperature impacts inverter performance and output power.

Contact and Support Information