Installation & Operation Manual
Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 8000TL-X and is the answer not in the manual?

Growatt MIN 8000TL-X Specifications

General IconGeneral
Rated Output Power8000W
Number of MPPT2
Protection DegreeIP65
Nominal AC Frequency50/60 Hz
AC Frequency Range45-55 Hz / 55-65 Hz
THD<3%
Nominal AC Voltage230V
CommunicationWiFi, RS485, USB
AC Voltage Range180 - 280 VAC
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Cooling

Summary

2 Safety

2.1 Intended Use and Hazards

Converts PV DC to grid-compliant AC; built to safety rules, but improper use is hazardous.

2.2 Personnel Qualification

Grid-tied system requires connection by qualified personnel after local authority approval.

2.3 General Safety Instructions

Inverters designed to international safety requirements; follow all instructions and cautions.

2.4 Assembly Warnings

Warnings about inspecting unit before installation, proper assembly, and grounding of PV modules.

2.5 Electrical Connection Safety

Warnings about live components, opening inverter, qualified personnel for electrical work, and residual voltage.

2.6 Operation Safety Warnings

Warnings about sealed connectors, hot surfaces, and incorrect PV plant sizing.

4 Unpacking and Inspection

5 Installation

5.1 Installation Safety Instructions

Safety precautions regarding fire, burns, radiation, electrical installations, and PV generator connection.

5.2 Location Selection Guidance

Guidance on choosing a suitable location considering weight, visibility, ventilation, and environment.

5.3 Inverter Mounting Procedures

Step-by-step instructions for mounting the inverter using a bracket and securing it to the wall.

6 Electrical Connection

6.1 Electrical Connection Safety

Safety warnings related to lethal voltages and electrostatic discharge during electrical connection.

6.9 AFCI (Optional)

6.9.2 AFCI Danger Information

Danger of fire from electric arc; do not deactivate AFCI; work on product during operation is prohibited.

6.10 Earth Fault Alarm

7 Commissioning

7.3 Advanced Settings

7.4 Communications Setup

8 Inverter Start-Up and Shut Down

9 Maintenance, Repair, and Cleaning

11 Trouble Shooting

11.1 OLED Error Messages

Information to provide when contacting Growatt for system or inverter faults displayed on OLED.

11.2 System Faults Diagnosis

Lists system faults like AFCI, leakage, voltage, and isolation issues with troubleshooting suggestions.

AC Grid Faults and Issues

Addresses faults related to AC voltage, connection, PE, and frequency with troubleshooting steps.

11.3 Inverter Warning Codes

Lists inverter warning codes, their meanings, and suggestions for resolving them.

11.4 Inverter Fault Codes

Lists inverter fault codes, their meanings, and suggestions for resolving them.

Other Inverter Faults

Details other inverter faults like bus sample, relay, temperature, DSP, EEPROM, GFCI, and AFCI self-test.

13 Decommissioning

14 Technical Data