4 PB
EMERGENCY OPERATION
DISASSEMBLY AND MAINTENANCE
In the case of power failure or when small quantities of liquid need to be transferred, it is possible to operate the pump manually, in the
following manner:
• Keep the trigger (9) of the dispensing nozzle pressed ;
• Activate the lever (8) repeatedly ;
• Proceed to the transfer.
WETTED COMPONENTS
POM, Polypropylene, Stainless Steel, Nitrile Rubber, Viton & PTFE
RECOMMENDED USE
Diesel, Kerosene, Water , Emulsions, Mineral & Synthetic Oils,
Heating Oils, Antifreeze etc.
This pump requires little maintenance, but we recommend the periodic inspection, and if necessary cleaning of the intake filter , and the state
of efficiency of the hoses and the dispensing nozzle, in order to ensure a long working life.
If the electric cable is damaged it must be replaced by a technically qualified person so as to prevent any risk.