MS, MMS
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
Other languages
http://net.grundfos.com/qr/i/96163721
www.motralec.com / service-commercial@motralec.com / 01.39.97.65.10

Other manuals for Grundfos MS 402

Question and Answer IconNeed help?

Do you have a question about the Grundfos MS 402 and is the answer not in the manual?

Grundfos MS 402 Specifications

General IconGeneral
BrandGrundfos
ModelMS 402
CategoryEngine
LanguageEnglish

Summary

MS, MMS Installation and Operating Instructions

Preparation

4.1 Checking and Refilling Motor Liquid

Instructions for checking and refilling the motor's internal liquid.

4.1.1 MS 402;4000 Motor Filling

Specific filling procedures for MS 402 and MS 4000 motors.

4.1.2 MS 6000 Motor Filling

Specific filling procedures for MS 6000 motors.

Preparation and Installation Orientation

4.1.3 MMS Motor Filling

Filling procedure for MMS6, MMS 8000, MMS 10000, MMS 12000 motors.

Liquid Temperatures and Cooling

4.3 Liquid Temperatures;Cooling

Table specifies maximum liquid temperatures based on motor and flow conditions.

Cooling Recommendations

Grundfos recommends installing motors above well screen for cooling.

Electrical Connection

5.2 Motor Protection Basics

Essential protection requirements: earthing and external mains switch.

Electrical Connection - Advanced Topics

5.1.1 Frequency Converter Operation

Connecting motors to frequency converters and related precautions.

5.2 Motor Protection Details

Specific motor protection requirements for single-phase and three-phase motors.

5.2.1 Single-Phase Motor Protection

Protection for MS 402 and MS 4000 single-phase motors.

5.2.2 Three-Phase Motor Protection

Protection strategies for MS and MMS three-phase motors.

Motor Protection Settings and Lightning Protection

5.2.3 Required Circuit Breaker Settings

Guidelines for setting motor-protective circuit breakers for optimal protection.

Cable Sizing

Single-Phase Motor Control and Connection

Three-Phase Motor Connection and Rotation Check

Star-Delta Starting and Cable Identification

Frequency Converters and Motor Installation

5.6.9 Frequency Converter Operation

Connecting three-phase MS motors to frequency converters.

Motor Installation

Fitting the Pump to the Motor

Maintenance and Fault Finding

9. Fault Finding

Troubleshooting guide for common motor faults like not running.

Motor and Cable Checks

10. Checking Motor and Cable

Procedures for checking supply voltage, current consumption, and winding resistance.