INSTALLATION INSTRUCTION MANUAL AND
MAINTENANCE FOR LED LED FLOODLIGHTING
Specifications are subject to change without prior notice
Page 1
USER INSTRUCTION
* GRUPPE LIGHTING had taken the outmost care in design and manufacture of its products in order to guarantee as far as possible,
maximum safety and risk-free operation when used correctly. Nevertheless, in compliance with accident prevention laws, users are
required to ensure that all personnel responsible for the installation, handling use and sale of products are totally familiar with the
information supplied by the company and fully acquainted with any necessary precautionary, must be made available, as and
when required to any company or persons engaged in the installation of GRUPPE LIGHTING products.
GENERAL
* This luminaire is designed for outdoor lighting service, and should not be used in areas of limited ventilation, or in high ambient
temperatures. Best result will be obtained if installed and maintained according to the following recommendations.
UNPACKING
* This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to comfirm.
CAUTION : Glass must be protected from surface chips and scratches. Even minor surface damage will reduce the breakage
resistance to a fraction of its initial strength.
WARNING
* Installation should be performed by qualified electrician in compliance with these instructions and applicable standards.
* Disconnect the mains power supply before installing or replacing the light source.
* Make sure that the rated voltage of the light source is compatible with the supply voltage.
* Make sure that the light source is compatible with the ambient conditions in which it must operate.
* Make sure that the mains supply circuit is equipped with protection devices.
* The safety of the fitting is guaranteed only by the proper use of the following instructions, so we recommend to keep them.
NOTES
* The supply cable must endure a temperature of 90° C.
* Avoid the location of the supply cable near hot components.
MAINTENANCE
WARNING : DANGEROUS VOLTAGES EXIST WITHIN THESE UNITS AND ALL PRECAUTIONS USUALLY OBSERVED IN HANDLING HIGH
VOLTAGE EQUIPEMENT SHOULD BE OBSERVED WHEN REPLACING LAMPS OR OTHERSWISE SERVICING LUMINAIRES. DISREGARDING THIS
WARNING COULD RESULT IN ELECTRICAL SHOCK AND POSIBBLE INJURY TO THE INDIVIDUAL INSTALLING OR SERVICING THIS EQUIPMENT.
In order to maintain high efficiency of reflectors and refractors, periodic cleaning on the outside of glass lens should be established with
frequency dependent on local conditions. Use a mild soap or detergent which is essentialy neutral (follow manufacturer’s
recommendation :PH approximately 6 to 8), nonabrasive, and which contains no chlorinated or aromatic hydrocarbons. Wash
thoroughly, using a soft cloth, or brush if necessary. Rinse in clean, cold water and wipe dry.
Materials/ Finishes
* Housing material
* Standard colour
* Glass protector
Characteristics
* Light source
* Optical assembly
* Ballast compartment
* IK protection degrees
* Electrical insulation
* Compliance
* Voltage
* Power correction factor
* Wattage
* Weight
* Colour temperature (CCT)
* Colour rendering (CRI)
* Life Span
MODEL :
Delta
LED Floodlight
: High pressure die cast aluminium alloy housing
: Grey
: Tempered clear glass
: Mid power LED
: IP 66
: IP 66
: IK 09
: Class 1
: IEC 60598-1, IEC 60598-2-5
: 100V – 277V / 50-60Hz
: > 0.9
: 10W - 240W
: 1.5kg – 10.0kg
: 3000k – 6000k
: > 70
: 50,000 hrs ( Based on light source)
Question and Answer IconNeed help?

Do you have a question about the Gruppe Delta and is the answer not in the manual?

Gruppe Delta Specifications

General IconGeneral
Power Consumption100W
Light SourceLED
Weight2.5 kg
Color Temperature5000K
Beam Angle120 degrees

Summary

User Instructions and Safety

General Operating Guidelines

Luminaire for outdoor use, avoid limited ventilation or high ambient temperatures for best results.

Unpacking and Handling

Inspect for transit damage. Protect glass from chips/scratches to maintain breakage resistance.

Installation Warnings

Installation by qualified electrician. Disconnect power, ensure voltage compatibility, and use protection devices.

Operational Notes

Supply cable must endure 90°C and avoid hot components. Keep instructions for safety.

Maintenance Procedures

High Voltage Warning

Caution: Dangerous voltages exist. Observe all high voltage precautions to prevent shock or injury.

Cleaning Instructions

Periodically clean glass lens with mild, neutral soap. Wash with soft cloth, rinse, and wipe dry.

Technical Specifications

Materials and Finishes

Housing: die cast aluminium alloy. Colour: Grey. Glass: Tempered clear glass.

Performance Characteristics

LED source, IP66/IK09 ratings, Class 1 insulation, 100-277V, PF>0.9, 50,000 hrs lifespan.

Technical Dimensions and Installation

Product Dimensions

Table detailing dimensions (a, b, c, d, e) for various wattage ranges (10-240W).

Installation Steps

Visual guide for installation and maintenance steps, numbered for clarity.