POWER Inverters
GSL-H-12KLV-US
PV Energy
Import
Today:
Total:
Today:
Total:
Discharge Energy
Today:
Total:
Today:
Total:
Consumption
Hybrid 5.0 inch Big Touchscreen LCD Display
Normal
0.1V 0W
10240W
Battery
PV
Backup Loading
Home Loading
Grid
75%
51.9V
237.4V
49.99Hz
4936W
2W
0W
237.6V
49.99Hz
0.1V 0W
0.1V 0W
Question and Answer IconNeed help?

Do you have a question about the GSL GSL-H-12KLV-US and is the answer not in the manual?

Summary

Safety

Safety Instruction

General safety guidelines for operating and maintaining the inverter safely.

Brief Introduction

System Solution

Explains various system application diagrams suitable for the inverter.

Installation

Packaging List & Storing

Lists all components included in the inverter package for unpacking and storage.

Location Selection and Installation

Provides requirements for choosing a suitable location and mounting the inverter.

Connection Overview

Details the system connection diagram and breaker selection for the inverter.

PV Connection

Instructions for connecting the photovoltaic (PV) strings to the inverter.

Battery Connection

Guides on connecting both power and communication cables for the battery.

Grid&EPS Load Connection

Instructions for connecting the inverter to the grid and EPS load for split-phase service.

Working with Generator

Information on connecting and configuring the inverter to work with a generator.

AC Coupling Installation Connection

How to connect the inverter for AC coupling with an existing grid-interactive solar system.

Parallel System Connection

Steps for connecting multiple inverters in parallel to expand capacity.

Monitor System Setup

Guides on setting up Wi-Fi, GPRS, 4G, or WLAN dongles for system monitoring.

Operation Guide

Operation Mode

Explains different working modes like Self-usage, Charge First, and AC Charge.

LCD Display

How to view inverter status, power, energy, alarms, and faults on the LCD.

Troubleshooting & Maintenance

Troubleshooting Based On LCD Displays

Using LCD information for diagnosing and resolving faults and warnings.

GSL GSL-H-12KLV-US Specifications

General IconGeneral
ModelGSL-H-12KLV-US
CategoryInverter
Rated Power12 kW
Output Power12 kW
Frequency60 Hz
CoolingFan Cooling
Operating Temperature-10°C to 50°C
Output Voltage120V/240V
Input Voltage Range40-60 V
ProtectionOverload, Short Circuit, Over Temperature
Input Voltage48V DC