The system is at a fully ready status where all detectors are activated in a working state.
This is for partial arming of the alarm system when there are people at home.
All sensors are deactivated and will not be respond to any events.
Alarm panel should be installed at a central location with best transmission to all the wireless sensors and accessories.
Diagram showing connections for Siren, PIR detector, Door contact, Power, Backup battery recharge switch.
SIM card installation is simple. Firstly remove the cover of SIM card slot at the back of the alarm panel.
Configure voice alarm phone numbers for up to nine groups.
Delete voice alarm phone numbers for the first to ninth groups.
Configure up to six phone numbers for receiving SMS alerts.
Delete SMS message phone numbers from the first to ninth group.
Modify the user password for system access.
Set the system delay time (0-99 seconds) after arming.
Set the delay time for alarming (0-99 seconds).
Configure the siren sound length from 0 to 20 minutes.
Enable or disable audible confirmation beep for remote control operations.
Set the system date and time.
Set scheduled arm and disarm times for up to four groups.
Define defense zone types (e.g., Normal, Stay, Intelligent) and siren behavior.
Configure wired alarm zones to NO or NC mode.
Enable/disable two-way alarm function for door sensors.
Configure SMS alerts for AC power disconnect.
Configure SMS notifications for arming/disarming events.
Enable or disable audible confirmation beep from the panel.
Adjust the siren volume from 00 to 99.
Enable keyboard password protection to lock the keypad.
Reset the system to factory default settings.
Query the currently saved voice alarm phone numbers.
Query the first to sixth group of SMS message phone numbers.
Query the current password of the alarm panel.
Query the delay time for arming (00-99) seconds.
Query the delay time for alarming (00-99) seconds.
Query the siren sounding time (00-20) minutes.
Query remote control audible confirmation setting for commands.
Query the scheduled arm and disarm times for up to four groups.
Query the zone types of 00-99 wireless defense zones.
Query the zone type of wired zones 51-54.
Query the system's most recent 72 disarmed records.
Query the system's most recent 102 alarming records.
Send SMS message to disarm the alarm panel.
Send SMS message to set the alarm panel to NORMAL ARM.
Send SMS message to set the alarm panel to STAY ARM.
Query the AC power status via SMS.
Query general alarm panel settings via SMS.
Query voice alarm phone numbers (1st to 9th group) via SMS.
Query SMS message phone numbers (1st to 6th group) via SMS.
Query the alarm panel system time via SMS.
Query scheduled arm/disarm status for groups 1-4 via SMS.
Query wireless defense zone type and siren setting via SMS.
Query settings for wired defense zones 51-54 via SMS.
Customize SMS messages for zone alarms.
Query customized SMS message content for zones 00-99.