-Individual cell voltage balancer for lithium batteries inside
G.T. POWER V5 has an individual-cell-voltage balancer built in so it does not need a separate
balancer when charging LiPo batteries.
-Maximum safety
Delta-peak sensitivity. The automatic charge termination program works on the principle of the
Delta-peak voltage detection.
Capacity limit: The charging capacity always calculated by multiple of the charging current and
time.If the charging capacity exceeds the limit the process will be terminated automatically when
you set the maximum value.
Temperature limit (*): The temperature of the battery on charging will raise by its internal
chemical reaction .If you set the limit of temperature the process will be expired forcibly when the
limit has reached.
Processing time limit: You can also restrain the max
imum process time to prevent from any
possible defect.
Input power monitor: To protect the car battery using as input power from being damaged the
voltage of it always monitored . If it drops below the lower limit the process will be ended
automatically.
-High- power and high- performance circuit
V5 employs the circuit that has max
imum output power of 50W.
As a result it can charge up to
14cells of NiCd/NiMH and 5series of LiPo batteries with maximum current of 5.0A.
*When using the thermal probe
Specifications
Operating voltage range: 10.018.0 V
Circuit power: max.50W
Charge current range: 0.15.0A
Current drain for balancing LiPo: 200mAh/cell
NiCd/NiMH battery cell count: 114 cell
Li-lon/Polymer cell count: 15 Series
Pb battery voltage: 2 to 12V
Weight: 360g
Dimensions: 130×98×30 mm