V12AM
Installation
Instructions
Walk Test LED
PCB
Electronics Module
Note: If internal EOL
resistors in use
connect the loop to
terminals 3 and 10
1 2 3 4 5 6 7 8 9 10
NC
ALARM
12 V
Power
NC
AUX
NC
TAMPER
T
E
S
T
C
T
R
L
+
Anti-Mask
Light Pipes
Connector Block
Switches
PIR Sensor
(Do not touch)
Declination
Indicator
0m 5m 10m 15m
2.3m
Lens
Module
Main Lens
Main Lens Screws
Tamper Switches
(loosen only, do not remove)
Lens Module
Front Cover
Cover Screw
PCB
A
A
A*
B
B
C
C
A
A
B*
B
Cable Entry
Cable Channel
Base
Knockout Holes:
A - Corner mounted
B - Flush mounted
C - Wall mounted using LPB2 brackets
For the off-the-wall tamper to be operational, screw must
be fitted in either A* or B*
Enabled Disabled
Enabled Disabled
10 m 15 m
10 m 15 m
Connected Off
Connected Off
Standard High Security
Standard High
On Off
- -
FACTORY DEFAULTS
1 2 3 4 5 6 7 8 9 10
No. Function
1 LED Enable
2 Pulse Count
3 PIR Gain 1
4 PIR Gain 2
5 HS EOL1
6 HS EOL2
7 Mode
8 AM Sensitivity
9 AM On/Off
10 Not Used
OFF
ON
Coverage Diagrams
0m 5m 10m 15m
10m
5m
0m
5m
10m
Question and Answer IconNeed help?

Do you have a question about the Guardall V12AM and is the answer not in the manual?

Guardall V12AM Specifications

General IconGeneral
MountingSurface mount
Housing MaterialABS Plastic
TypeMagnetic Contact
Alarm OutputN/C
Power SupplyDC

Summary

Detector Settings and Configuration

Detector Voltage Specification

Details the voltage requirements for the detector, including typical and maximum DC voltages.

Detector Mounting Guidelines

Provides instructions and considerations for securely mounting the detector unit.

Pulse Count Configuration

Explains how to set the pulse count for the PIR sensor, affecting sensitivity and false alarm rejection.

PIR Gain Adjustment

Describes the adjustment of PIR sensor gain levels (Gain 1 and Gain 2) for optimal detection.

High Security EOL Settings

Details the configuration of High Security End-of-Line (EOL) resistors (HS EOL1 and HS EOL2).

Operating Mode Selection

Explains the different operating modes available for the detector.

Anti-Mask Sensitivity and Control

Covers the setup of Anti-Mask (AM) sensitivity and the AM On/Off function.

Wiring and Connections

Provides guidance on connecting the detector's wiring to the control panel and other devices.

Front Cover Removal Procedure

Instructions on how to safely remove the detector's front cover for installation or maintenance.

Anti-Mask Functionality

Details the operation and purpose of the Anti-Mask feature.

Installation and Adjustment Procedures

Coverage Diagrams Explanation

Illustrates the detection range and pattern of the V12AM detector.

High Security Loop Configuration

Details how to configure the detector for high security loop applications.

Power Supply Verification

Guidance on checking the detector's power supply for correct operation.

PIR Sensor Adjustment

Instructions for fine-tuning the PIR sensor's detection performance.

Declination Angle Adjustment

Describes how to adjust the detector's declination angle for optimal coverage.

Lens Module Replacement

Procedure for replacing the detector's lens module.

Installation Summary Checklist

A summary of key steps and checks for completing the installation.

Troubleshooting and Accessories

Troubleshooting Common Issues

Provides solutions for common problems encountered during installation or operation.

Available Accessories

Lists optional accessories compatible with the V12AM detector.