Part No. 320998-0B
Installation Instructions
Guardall Limited
Lochend Industrial Estate
Newbridge, Edinburgh EH28 8PL
Technical Hotline: 0131- 333-3802
Website: www.guardall.com
Voltage: 12 V (9 V to 16 V dc)
Current: Quiescent – 14 mA @ 12V
Max – 30 mA @12V (All LEDs ON)
Alarm, Aux &
Tamper:
Normally closed (NC). Rated at 24 V dc,
50mA
Test Input: Positive supply to enable LEDs and control
Remote Self Test
Control Input: Positive supply for system Set. Otherwise
Unset
Microwave range: 50% to 100% of range via potentiometer
1. Technical Speci cation
See datasheet for full information
1
5
7
2
9
6
4
10
3
Diagram 1 - Unit Explanation
1. Cover Screw (loosen only - do not remove)
2. Microwave Range Control
3. PCB Retaining Screw
4. PIR Detector (do not touch)
5. Cover Tamper
6. Declination Indicator
7. LEDs
8. Off the Wall Tamper Connection
9. Terminal Block
10. Cable Knockout Positions
9 m
0 m
9m
0m 3m 6m 9m 12m 15m
2.3m
Diagram 4 - Coverage Diagrams
Volumetric Side View 15m
0m 3m 6m 9m 12m 15m
Diagram 2 - Terminal block
1 2 3 4 5 6 7 8 9 10
NC Aux Ctrl
12 V
Test
- +
NC
Alarm
NC
Tamper
Volumetric Plan View 15m
Diagram 3 - Tamper Switch
Off the wall tamper tting is required for EN Grade 3
- the screw should be tted in location A or C.
DTSx+
8
Question and Answer IconNeed help?

Do you have a question about the Guardall DTSx Plus and is the answer not in the manual?

Guardall DTSx Plus Specifications

General IconGeneral
BrandGuardall
ModelDTSx Plus
CategorySecurity Sensors
LanguageEnglish

Summary

Unit Explanation

Cover Screw

Loosen only, do not remove.

Microwave Range Control

Control for adjusting microwave range.

PCB Retaining Screw

Screw for retaining the PCB.

PIR Detector

Passive Infrared detector component.

Cover Tamper

Tamper switch for the unit cover.

Declination Indicator

Indicator for declination.

LEDs

Light Emitting Diodes for status indication.

Off the Wall Tamper Connection

Connection point for off-the-wall tamper.

Terminal Block

Block for electrical connections.

Cable Knockout Positions

Designated positions for cable entry.

Tamper Switch

Off the Wall Tamper Fitting

Required for EN Grade 3; screw in location A or C.

Coverage Diagrams

Volumetric Plan View 15m

Diagram showing coverage in plan view up to 15m.

Volumetric Side View 15m

Diagram showing coverage in side view up to 15m.

Technical Specification

Voltage

Operating voltage range: 9 V to 16 V dc.

Current

Quiescent: 14 mA; Max: 30 mA @ 12V.

Alarm, Aux & Tamper

Normally closed (NC) contacts, rated at 24 V dc, 50mA.

Test Input

Positive supply to enable LEDs and control Remote Self Test.

Control Input

Positive supply for system Set.

Microwave range

Adjustable via potentiometer from 50% to 100%.

Enclosure Compliance and Safety

EN50131 Compliance

Meets TS50131-2-4:2004, Grade 3, Class II with specific switch settings.

Declaration of Conformity

Guardall Ltd declares compliance with EU Directive 1999/5/EC.

Intended Use

For use within a building as an intruder detection device.

Safety Information

Power feed must be fused at 5A or less.

Installation and Configuration

Installation Location

Recommended mounting height is 2.3m; ensure clear field of view.

Walk testing

Procedure for testing PIR and microwave coverage.

Operating Feature Selection

Selection of functions via DIP switches.

SW1: LED enable

Enables or disables LED indications.

SW2: Pulse Count

Enables pulse count detection in harsh environments.

SW3: Microwave Day Disable

Disables microwave when system is Unset.

SW4: Anti-mask / Fault Output

Configures anti-masking and fault signaling.

SW5: Anti-Mask Sensitivity

Adjusts anti-mask sensitivity, set to OFF for harsh environments.

SW6: Anti-Stealth

Enhances detection for high security applications.

Remote Self Test (RST)

Generates a test when TEST Input is taken high to low.

Alarm Memory

Memorizes alarms when System Set or Unset with SW1 OFF.

Memory reset

Occurs next time the system is set.

LED Mode Setting

Defines LED behavior based on system state and switch settings.

LED Indications

Details on Red, Green, and Yellow LED behavior.

Product Warranty

Warranty

Covers defects in workmanship and materials.

Related product manuals