16. REGULAR EXPLOITATION
IMPORTANT: due to the fact the door of the hearth has a remarkable size, we suggest you to open
the door very slowly, to avoid the exit of smokes and flames.
For safety reasons the door of the hearth can be opened during the stove operation only for
the loading of the fuel. The hearth door must always remain closed during operation.
Before opening the hearth door, open the primary air regulator, open the door slowly, load the fuel,
close the door and after about 5 or 10 minutes close the primary air control.
Heat emission is adjusted via regulators located on the front side.
They must be opened according to the calorific need. The best combustion is reached when most of
the air for the combustion passes through the regulator of secondary air.
Never overload the stove (compare the technical table - max. quantity of loadable fuel).
The warranty does not cover the damages due to overheating of the equipment.
You should always use the stove with the door closed in order to avoid damages due to overheating.
The adjustment of the regulators is as follows:
Fuel Secondary air (A1) Primary air (B1)
Wood Open Closed
Mass of fuel hourly 3.2-3.3 kg/h 3.2 -3.3kg/h
Besides the adjustment of air for the combustion, the intensity of combustion and then the calorific
value of your stove depend from the chimney. A good flue of requires a more reduced adjustment of
air for the combustion.
To verify the good combustion of the stove, check if the smoke coming out from the chimney and
if the smoke is gray or black, it means that the combustion is not complete (a greater quantity of
secondary air is necessary).