EasyManua.ls Logo

Gude GOA 65 L - User Manual

Gude GOA 65 L
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GOA 65 L
# 40845
©
Güde GmbH & Co. KG - Birkichstraße 6 - D-74549 Wolpertshausen – Deutschland
Deutsch D - 3-6
Originalbetriebsanleitung
M
auernut- und Dehnfug-Fräse
English GB - 7-10
Translation of original operating instructions
Masonry chaser
Français F - 11-14
Traduction du mode d’emploi d’origine
chaser Maçonnerie
Čeština CZ - 15-18
Překlad originálního návodu k provozu
zdivo Chaser
Slovenčina SK - 19-22
Preklad originálneho návodu na prevádzku
murivo Chaser
Nederlands NL - 23-26
Vertaling van de originele gebruiksaanwijzing
M
etselwerk chaser
Italiano I - 27-30
Traduzione del Manuale d’Uso originale
Massoneria chaser
Magyar H - 31-34
Az eredeti használati utasítás fordítása
Kımőves chaser
Slovenščina SLO - 35-38
Prevod originalnih navodil za uporabo
Zidarski Chaser
Hrvatski HR - 39-42
Prijevod originalnih uputa za uporabu.
Ureðaj za hvatanje i usisivanje ulja
Bosanski BIH - 43-46
Prijevod originalnih uptstava za upotrebu.
Ureðaj za hvatanje i usisavanje ulja
Româneşte RO - 47-50
Traducerea manualului de exploatare original.
Dispozitiv de captare si aspirare a uleiului
Български BG - 51-54
Превод на оригиналната инструкция
Уред за захващане и изсмукване на масло
EG-KONFORMITÄTSERKLÄRUNG - 55-56
EC-DECLARATION OF CONFORMITY

Questions and Answers

  • K
    Kristin FischerAug 10, 2025
    What to do if the air gauge shows sufficient depression but the oil is not sucked in my Gude GOA 65 L?
    • M
      Matthew NicholsAug 10, 2025
      If the air gauge shows sufficient depression but the oil is not sucked, it could be due to several reasons. The rubber ring from the oil suction connection might be worn, the oil suction sensing head might be damaged, or the oil temperature might be too low. Also, check if the oil suction valve is working correctly and if the oil suction ducting is damaged. Replace the packing ring on the suction hose and the cover of the oil suction sensing head. Wait until the temperature reaches normal levels. Open the valve on the oil suction ducting, and if the ducting is clogged, clean it out.
  • C
    Chad PerezAug 20, 2025
    How to fix no vacuum generated in Gude GOA 65 L Service Equipment?
    • J
      Jessica MillerAug 21, 2025
      If no vacuum is generated, it may be due to air escaping because the ball on the valve seat is corroded. First, verify the air is being emptied into the storing container. If not, check the sealing. If air escapes at the sealing, tighten the connected auxiliary part or replace the sealing. If the ball is corroded, replace the entire unit. Ensure all valves are closed during this check.
  • A
    Amber DeanAug 29, 2025
    Why does the pressure control valve indicator quickly drop in Gude Service Equipment?
    • Q
      qbrownAug 29, 2025
      The pressure control valve indicator might quickly drop after vacuum generation due to air escaping. Check the storing container whether the air is emptied there. If it is not the case check the sealing. If air escapes at the sealing tighten the connected auxiliary part or replace the sealing. If the ball is corroded then replace the entire unit. All valves should be closed at checking.

Gude GOA 65 L Specifications

General IconGeneral
Number of outputs1
Number of inputs1
Input voltage230 V
Output voltage230 V
Input frequency50/60 Hz
Maximum input current65 A
Maximum output current65 A
MountingDIN rail
Height90 mm
BrandGude
ModelGOA 65 L