Reversal of flaps or slats position selection when surface is in motion is
not recommended. The system should come to a complete stop prior
to reversing flaps or slats travel.
If a malfunction occurs in slats extension/retraction system, they may
be disabled and bypassed by pressing SLAT BYPASS ARM
pushbutton, on the pedestal. Slats operation is, then, stopped even
during motion. Krueger flaps stay retracted if slats are not fully
extended. The slats bypass function is inoperative when slats are fully
extended. Pressing SLATS BYPASS ARM pushbutton removes the
flaps and slats primary drive motor protections. Therefore, it should be
used only once, after slats system failure.