Installation and Maintenance guide
GJPACW1V-15/20/30/40/60
GJPACW1-15/20/30
EN
________________________________________________________________________________________________
Gullberg & Jansson AB | Smältaregatan 6 | SE - 263 39 Höganäs
Tel: +46 (0) 42 34 05 90 | Fax: +46 (0) 42 34 02 10 | E-mail: info@gullbergjansson.se | www.gullbergjansson.se
Question and Answer IconNeed help?

Do you have a question about the Gullberg Jansson GJPACW1V-15 and is the answer not in the manual?

Gullberg Jansson GJPACW1V-15 Specifications

General IconGeneral
BrandGullberg Jansson
ModelGJPACW1V-15
CategorySwimming Pool Pump
LanguageEnglish

Summary

General information

Product description

Overview of air/water heat pumps for swimming pools and spa pools.

Functional principle

Explains how the heat pump works and its operational requirements.

Important information

Key points on transport, storage, installation, usage, maintenance, and fault tracing.

Transport and storage

Guidelines for safe transport and storage to prevent damage.

Installation

Requirements for outdoor installation, firm placement, drainage, and air circulation.

Use and operation

Information on factory settings and general operation of the unit.

Maintenance procedures

Essential steps for winter draining and regular checks to ensure performance.

Service and support

Guidance on contacting installation engineers for faults and stating product numbers.

Miscellaneous

Notes on repairs, spare parts, and combining with solar collectors.

Checklist installation

A checklist to ensure all steps for proper heat pump installation are followed.

Guarantee conditions

Conditions for system transport, storage, installation, and usage for valid guarantee.

Safety Regulations

Crucial safety instructions for handling, installing, and using the heat pump.

Installation

Outline diagram

Visual representation of the heat pump's connection to the pool system.

Positioning the unit

Ideal conditions and placement guidelines for optimal heat pump performance.

Set up

Requirements for firm base, noise consideration, drainage, and air circulation for setup.

Distance to the pool

Discusses pipe routing, insulation, and heat loss impact on running time.

Leading off condensation water

Explains condensation formation and the importance of proper drainage.

Pipe connections

Details on connecting the heat pump to the pool circulation system using union couplings.

Bypass coupling

Recommends bypass fitting for flow adjustment and service, with adjustment steps.

Electrical installation

Instructions for electrical connection, including safety switches and earth connection.

Starting up the unit

Step-by-step procedure for the initial start-up of the heat pump.

Use and operation

Description of LED controls

Explains the meaning of the LED display and various buttons for unit control.

How to change operating parameters

Step-by-step guide on how to adjust the heat pump's operating parameters.

How you select the operating mode

Instructions on switching between heating and cooling modes.

Explanation of sensor values

Details on interpreting various sensor readings displayed by the unit.

Setting the time

Procedure for setting the current time on the heat pump's display.

Timer setting and activation

How to set timers for automatic start and shutdown of the heat pump.

Deactivation of the timers

Steps to disable or deactivate the set timers.

Maintenance, service and fault tracing

Winter drainage

Crucial steps for winter draining to prevent freezing damage and maintain guarantee.

Maintenance

Regular cleaning of filters, checking ventilation, and heat exchanger cleaning for optimal function.

Error code table

Lists error messages, their causes, and recommended actions for troubleshooting.

Fault charting table

A table detailing common operating disturbances, their causes, and corrective actions.

Technical specification

Connection key Chiller 300.2

Details the designation and description of each terminal connection for the Chiller 300.2.

Wiring diagram

Provides the wiring diagram for one-phase and three-phase connections of the heat pump.

Component placement (GJPACW1V models)

Illustrates and lists the placement of various components within the GJPACW1V heat pump.

Technical data (GJPACW1V models)

Presents detailed technical specifications for GJPACW1V models.

Dimensions and connections (GJPACW1V models)

Provides dimensional drawings and connection details for GJPACW1V models.

Component placement (GJPACW1 models)

Illustrates and lists the placement of various components within the GJPACW1 heat pump.

Technical data (GJPACW1 models)

Presents detailed technical specifications for GJPACW1 models.

Dimensions and connections (GJPACW1 models)

Provides dimensional drawings and connection details for GJPACW1 models.

Appendices

Questions and answers

Addresses common user questions regarding temperature setting, performance, and maintenance.