Operation &
Maintenance
Manual
Issue:
10
A6ML0066 Euroblast SF Instruction Manual
Date:
05/2019
Page: 36
Airjet
Media entry
The media entry connection should be withdrawn from the gun body and inspected for wear on a
regular basis.
The airjet should be withdrawn from the gun body after 8 hours blasting to establish the
wear pattern on its outer surface. When wear has become noticeable, the fitting should be
rotated to the next unworn section. When wear has occurred around the whole
circumference, the airjet should be replaced.