7.1.9 Topping up media
Top up the media levels as required as media is consumed. This can be roughly gauged from the
waste bin on the dust collector. Regular additions of small quantities of media maintain an even
particle size and assist in producing consistent results.
7.1.10 Filter cleaning
Filter cleaning must be carried out on a regular basis. Initially this should be carried out every four
hours, until a working pattern is reached. The table below shows the different cleaning mechanisms
on the various dust collector models:
THE MOTOR SHOULD BE SWITCHED OFF WHEN USING THE CLEANING
MECHANISM ON THE 41, C400 AND C600 DUST COLLECTORS
41 Dust collector
The filter cleaning system is manual. Pull and push
the knob back and forth to shake the filter clean.
C400 and C600 Dust collector
The filter cleaning system is manual. Push the
button to release the compressed air from the
pressure vessel to knock the dust from the filter.
C800 Dust collector
This has an automatic filter cleaning system. A
controller automatically releases compressed air
from the pressure vessel to knock the dust from the
filters.
The release interval is set to 30 secs in the factory.
See appendix for controller manual.