7.1.10.7 Bin Balance Breather Sock
When changing the filter cartridges on a dust collector fitted with a bin
balance pipe, check that the filter sock is in place and not full of media.
The filter sock is attached to the end of the bin balance pipe and is
there to prevent dust from being drawn into the clean side of the dust
collector.
If a plastic bin liner has not been used then dust will be drawn up the
bin balance pipe into the sock.
It is essential therefore that a plastic bin liner is always used.
Check that the sock is firmly attached and not full of dust. The sock
prevents dust from contaminating the clean side, as dust will be drawn
out of the dust collector bin if a plastic bin liner is not used.