GENERAL PRODUCT INFORMATION
FEATURES
Safely stores most U.S and International SCBA brands and sizes.
Patented auto-lock system holds the SCBA securely in place.
Patented one-touch release handle (no straps or clamps to snag).
Easy adjust components.
Meets NFPA 1901 standards and requirements of EN 1846
SAFETY INFORMATION
DANGER indicates a hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, COULD result in a death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, COULD result in minor or moderate injury.
NOTICE is used to address practices not related to physical injury.
SAFETY INSTRUCTIONS (or equivalent) signs indicate specific safety related instructions or procedures.
TOOLS REQUIRED




TOP CLAMP
LOCKING NUT
PIVOT ARM LOCKING PLATE
WARNING LABEL
CENTER GUIDE
CYLINDER SUPPORT ASSEMBLY
VALVE CUP ATTACHMENT SCREW
CLAMP ADJUSTMENT SCREWS
QUICK HEIGHT ADJUSTMENT LEVER
LATCH ASSEMBLY
ALUMINUM MOUNTING CHANNEL
CENTER GUIDE ADJUSTMENT SCREWS
CYLINDER SUPPORT ATTACHMENT SCREWS
VALVE CUP (OPTIONS AVAILABLE)
Figure 1
SETUP AND ADJUSTMENT
AIR CYLINDER BRAND AND CYLINDER DIMENSION CHART
Identify air cylinder size before adjusting SecureALL
®
Table 1
CYLINDER TYPE DIAMETER CIRCUMFERENCE
VALVE CUP
NOTCH
POSITION
CYLINDER
SUPPORT
POSITION
TOP CLAMP
POSITION
BOTTLE SPECIFIC SERVICE KITS
SEE PAGE 2
AVON (ISI)
2216PSI ALUMINUM

6 ³
171mm
21 ¹

FRONT LOWER E 
2216PSI COMPOSITE

6 ³
171mm
21 ¹

FRONT UPPER C




16 
429mm
FRONT UPPER A


6 ³
161mm
20 ¹

FRONT LOWER B

60 MINUTE
6 

21 

FRONT LOWER C
DRAEGER
2216PSI ALUMINUM

6 
171mm
21 ¹

FRONT LOWER E 
2216PSI COMPOSITE

6 
168mm
20 ¹

FRONT UPPER C




16 
429mm
FRONT UPPER A


6 ¹

20 

FRONT LOWER B

60 MINUTE
7''
178mm


FRONT LOWER C
HONEYWELL (SURVIVAIR, SPERIAN)
2216PSI ALUMINUM

6 
171mm
21 ¹

FRONT LOWER E 
2216PSI COMPOSITE

6 ³
171mm
21 ¹

FRONT UPPER C


6 ³
171mm
21 ¹

FRONT LOWER C


¹
140mm
17 ¹

FRONT UPPER A


6 ³
162mm


FRONT LOWER B


6 ³
171mm
21 ¹

FRONT UPPER C

60 MINUTE

178mm


FRONT LOWER C
INTERSPIRO
2216PSI ALUMINUM

6 ³
171mm
21 ¹

REAR LOWER E 
2216PSI COMPOSITE

6 
168mm
20 ¹

REAR UPPER C


¹
140mm
17 ¹

REAR UPPER A


6 
160mm
19 ¹

REAR LOWER B

60 MINUTE

178mm


REAR LOWER C
MSA* M7 & G1 See page 2
2216PSI ALUMINUM

6 ³
171mm
21 ¹

FRONT UPPER E 
2216PSI COMPOSITE

6 ³
171mm
21 ¹

FRONT UPPER B


6 ³
171mm
21 ¹

FRONT LOWER B




16 
429mm
FRONT UPPER A


6 ³

19 
494mm
FRONT LOWER B


6 ¹

19 
498mm
FRONT LOWER B

60 MINUTE
7 ¹
181mm
22 

FRONT LOWER C



127mm
¹

N/A UPPER A 




18 ¹
478mm
N/A UPPER B 

60 MINUTE
6 

19 
494mm
FRONT LOWER B


6 

21 

FRONT LOWER C
SCOTT* See page 2
2216PSI ALUMINUM

6 
167mm
21 ¹

FRONT LOWER E 
2216PSI COMPOSITE

6 ³
171mm
21 ¹

FRONT UPPER C


6 ³
171mm
21 ¹

FRONT LOWER C




16 
429mm
N/A UPPER A 


6 

19 
494mm
FRONT LOWER B


6 ¹

19 
498mm
FRONT UPPER B

60 MINUTE
6 

21 

FRONT LOWER C



127mm
¹

N/A UPPER A 




18 ¹
478mm
N/A UPPER B 

60 MINUTE
6 

19 
494mm
FRONT LOWER B


6 

21 

FRONT LOWER C
VALVE CUP INSERT CHOICE BY BRAND
SECUREALL® BRACKET ADJUSTMENT INSTRUCTIONS
1. VALVE CUP ADJUSTMENT
Standard insert 8920-068 is factory installed on all SecureALL
®
brackets. See Figure 2.
VALVE CUP ADJUSTMENT FOR INTERSPIRO ONLY



Figure 2
1
2


REARFRONT
2. CYLINDER SUPPORT POSITION ADJUSTMENTS
1. Measure overall SCBA cylinder length (including valve).

use upper mounting holes.

use lower mounting holes as shown in Figure 4.
2. If applicable, remove attachment screws, position cylinder
support assembly, and reinstall screws.
UPPER
LOWER
WARNING
The installer is liable for SCBA bracket adjustment. Failure to properly tighten fasteners could

Figure 4
®
3. TOP CLAMP ADJUSTMENT
1. Measure the circumference of the SCBA bottle and refer to Table 1 for Top Clamp Position.
2. Place valve in foot cup and push bottle into SecureALL.
®
 

4. Replace and tighten adjustment screws in the appropriate clamp adjustment holes.
 Remove and reinstall the SCBA assembly to confirm adjustment for cylinder size. Ensure there are no
obstructions that could prevent the cylinder from locking up against the clamp.
WARNING
Installer is liable for SCBA bracket adjustment. Failure to properly tighten fasteners could result
in clamp sliding forward and accidental SCBA release.
A
B
C
D
E


NOTICE: For additional assistance contact your OEM, dealer OR


H.O. BOSTROM COMPANY, INC.
818 PROGRESS AVE, WAUKESHA, WI 53186
WWW.HOBOSTROM.COM
ADJUSTMENT INSTRUCTIONS FOR THE
SECUREALL® SCBA LOCKING SYSTEM
TO BE REMOVED BY THE CUSTOMER ONLY
SECUREALL® BRACKET COMPONENTS
See Page 2
Question and Answer IconNeed help?

Do you have a question about the H.O. BOSTROM SECUREALL and is the answer not in the manual?

Summary

SecureALL SCBA Locking System Overview

General Product Information

Overview of the SecureALL SCBA Locking System's features, safety standards, and tools required for installation.

Safety Information and Hazard Classifications

Details hazard classifications (DANGER, WARNING, CAUTION) and general safety practices for system use.

SecureALL Bracket Components Identification

Illustrates and labels the various components of the SecureALL bracket system.

SecureALL Bracket Setup and Adjustment

Air Cylinder Brand and Dimension Chart

Reference table for identifying SCBA cylinder brands, dimensions, and corresponding valve cup positions.

SecureALL Bracket Adjustment Instructions

Step-by-step instructions for adjusting the SecureALL bracket components for proper SCBA fit.

Valve Cup Adjustment Procedure

Instructions for adjusting the valve cup, including a specific procedure for Interspiro SCBA with angled valves.

Cylinder Support Position Adjustments

Guide on how to adjust the cylinder support assembly based on SCBA cylinder length using mounting holes.

Top Clamp Adjustment Procedure

Procedure for adjusting the top clamp to ensure a correct and secure fit for the SCBA cylinder.

SecureALL System Operation and Adjustments

Bottle Length Height Adjustment

Details on adjusting the clamp assembly height to match the SCBA cylinder length for secure fitting.

Optional SecureALL and Shroud Position Adjustments

Instructions for optimizing bracket and shroud placement for user comfort and SCBA size accommodation.

Cable Attachment and Sensitivity Adjustment

Details on attaching and adjusting the release cable for optimal sensitivity and operation.

Operating Instructions: Storing and Removing SCBA

Step-by-step guides for securing SCBA into the bracket and releasing it for use.

Troubleshooting Common Issues

Provides guidance on common issues, such as latch engagement problems, and their solutions.

Bottle Specific Service Kits

Examples and identification of various service kits available to adapt the SecureALL® to different cylinder valves.

SecureALL System Service Kits

Lists available service kits for the SecureALL system, including release handle kits and bracket mounts.

H.O. BOSTROM SECUREALL Specifications

General IconGeneral
BrandH.O. BOSTROM
ModelSECUREALL
CategoryOther