Copyright 11/04 – Hacker Motor GmbH 3
Install the speed controller in the model so that it is isolated from vibration
and shock, using Velcro or double sided foam tape. Allow space around it for
cooling. Make sure that there is sufficient cooling of the motor and speed
controller by ducting air through adequate cooling holes from the outside
airflow. Main power packs should be connected at one attempt
.
Die X-Drehzahlsteller sind im Auslieferungszustand optimal für Hacker-Brushless A20-Motoren eingestellt!
The X-speed controllers have an optimal default setup for A Series Motors.
Einstellungen im Auslieferzustand:
Factory default settings:
Bremse / Brake: Aus/Off
Akku-Typ / Battery type: 3 Li-Poly (ca. 7,8V)
Unterspannungsabschaltung / Under voltage: Zurückregelung/Reduce power
Gasannahme / Acceleration : Verzögert/delayed
Timing: Auto
Frequency: 8KHz
Normale Inbetriebnahme:
Gasknüppel auf Motor-Aus-Position, Akku anschließen, ein Beep für Bremse, zwei Beeps für Bremse aus
Normal start up:
When throttle stick is off, connect battery pack, and you will hear one beep
for Brake on or two tones for Brake off.
Für andere Einstellungen lesen Sie bitte nachfolgende Anleitung.
For changing the default setup, please read the following manual