EasyManua.ls Logo

hadewe HELIUS-40 - User Manual

hadewe HELIUS-40
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
OWNER’S MANUAL
HADEWE HELIUS-40
Speed range: 7000 – 40,000rpm
TABLE OF CONTENTS
Section Page
General Guidelines
1
Safety Information
2
Standard Operating Procedures
3
Maintenance & Care
7
Equipment Specifications
12
For more information or for customer support contact your local dealer or call
(800) 361-3079

Questions and Answers

  • P
    porterfrederickAug 13, 2025
    Why won't my hadewe HELIUS-40 equipment turn on?
    • M
      Michael EllisAug 13, 2025
      If your hadewe Pedicure Spa equipment isn't turning on, there are a few things to check: * Make sure the cable is properly plugged into a working wall socket. * Verify that the main power button on the back of the unit is switched ON. * Try pulling the footswitch out of the socket to see if that resolves the issue.
  • C
    charles54Aug 16, 2025
    Why is my hadewe HELIUS-40 handpiece vibrating and noisy?
    • J
      josephpattonAug 16, 2025
      If your hadewe Pedicure Spa handpiece is vibrating excessively or making a lot of noise, it could be due to: * Using bent tools or burrs. Try a different tool to see if this corrects the problem. * Exceeding the maximum allowed speed for the tool. Check the tool manufacturer’s recommended speed and decrease the speed on the control unit accordingly.
  • M
    Michael HutchinsonAug 20, 2025
    What to do if my hadewe HELIUS-40 Pedicure Spa burr stops suddenly?
    • P
      paulramirezAug 20, 2025
      If the burr on your hadewe Pedicure Spa stops suddenly, it may be due to the motor overheating. Let the unit rest for 10-15 minutes, then try again. If the motor then operates normally, try working with less pressure on the handpiece.
  • M
    Matthew GoodAug 25, 2025
    Why is my hadewe HELIUS-40 Pedicure Spa handpiece getting so hot?
    • X
      xericksonAug 25, 2025
      If your hadewe Pedicure Spa handpiece is becoming very hot during operation, it is likely that too much pressure is being applied during use. Avoid pressing too hard; instead, let the tool do the work.
  • B
    Bonnie GarciaAug 28, 2025
    What to do if the suction stops suddenly on my hadewe Pedicure Spa?
    • D
      Daniel RiceAug 28, 2025
      If the suction in your hadewe Pedicure Spa stops suddenly, it could be that the suction motor is overheating. Check that the filter bag is not full and that there is no obstruction of airflow for the vacuum. Allow the motor to cool for 10-15 minutes and then try again.
  • T
    Tristan SchmittSep 1, 2025
    Why is it difficult to insert a tool/burr into my hadewe HELIUS-40?
    • H
      htaylorSep 1, 2025
      If you're having difficulty inserting a tool or burr into your hadewe Pedicure Spa, consider the following: * You might be using bent tools. Use a different tool to test this. * The chuck could be dirty. Clean the chuck according to the instructions in the manual.
  • A
    Amanda FloydSep 4, 2025
    What to do if my hadewe Pedicure Spa tool/burr does not spin?
    • J
      Jason McculloughSep 4, 2025
      If the tool or burr in your hadewe Pedicure Spa is not spinning, check these: * Ensure the chuck is not open. Slide the button on the handpiece back to lock the chuck. * Verify the chuck is tightened well, according to the instructions in the manual.
  • H
    heatheringramSep 8, 2025
    Why is the button on the handpiece of my hadewe HELIUS-40 hard to move?
    • J
      Jessica JacksonSep 8, 2025
      If the button on the handpiece of your hadewe Pedicure Spa is difficult to move, the chuck may be dirty. Clean the chuck according to the instructions in the manual.

Summary

General Guidelines

Using the HELIUS-40

Instructions for safe and proper operation of the HELIUS-40, including setup and usage guidelines.

Safety Information

Important Safety Notes

Key safety instructions and warnings to ensure user and patient safety during equipment operation.

Getting to Know the HELIUS-40

Standard Operating Procedures

Initial Setup

Steps for correctly installing and preparing the HADEWE HELIUS-40 for use.

Using the Equipment

Detailed instructions on how to operate the HELIUS-40, including speed and suction settings.

Changing Rotatools

Procedure for safely replacing the tool or burr in the handpiece chuck.

Controlling Speed and Rotation

Guidance on adjusting speed and changing rotation direction for optimal performance.

Optional Foot Switch

Instructions for connecting and using the optional foot switch accessory.

Maintenance & Care

Cleaning the HELIUS-40

Daily and post-treatment cleaning procedures for the HADEWE HELIUS-40 unit and handpiece.

Changing the Filter Bag

Steps for replacing the suction filter bag to maintain optimal vacuum performance.

Monthly Maintenance

Periodic maintenance tasks, including filter exchange and sealing washer replacement.

Cleaning the Handpiece

Detailed instructions for disassembling and cleaning the handpiece components.

Cleaning the Clamping Chuck

Procedure for cleaning the handpiece chuck to ensure proper tool insertion and operation.

Helpful Advice

Practical tips and warnings to prevent damage and ensure longevity of the handpiece.

Troubleshooting

Common problems, their probable causes, and recommended solutions for the HELIUS-40.

Equipment Specifications

hadewe HELIUS-40 Specifications

Control Unit HELIUS-40

Power IconPower
power supply voltage115V AC
output power550W
voltage potential (output)5-27V
Fuse Specifications IconFuse Specifications
primary fuse F14.0A delayed-action
primary fuse F3630mA delayed-action
secondary fusethermal
Performance IconPerformance
suction capacity300-600 mmWs
noise level<64dBA at 1m distance
protection class1
Weight and Dimensions IconWeight and Dimensions
weight4.4 kg
width257 mm
height140 mm
depth257 mm

Suction-Handpiece

Power IconPower
power supply voltage5-27V DC
speed range7000 – 40, 000 rpm
Weight and Dimensions IconWeight and Dimensions
weight160 g
length160 mm
handpiece diameter17.5 mm – 22 mm