Specification   
                              
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS 
Refrigerant
circuit
Refrigerant type  R32
Refrigerant charge  KG 1.0
Maximum allowable distance 
between indoor and  outdoor 
m
30(double)
20(single)
Maximum allowable level difference  m 15
Refrigerant control  EEV  
Piping connections 
(external diameter) 
liquid mm 6.35
gas mm 9.52
drain mm 16
Heat insulation type  Both liquid and Gas pipes 
Max. piping Length  m
Max. Level Difference  m 15
Chargeless m 20
Amount of Additional Charge of Refrigerant  g/m 20
 
Note: the data are based on the conditions shown in the table below 
htgnelgnipiPgnitaehgnilooc
Indoor: 27 DB/19 WB
Outdoor: 35 DB/24 WB
Indoor:20 DB
Outdoor: 7 DB/6 WB
5m
3 Sensors list   
type Description Qty
itcetedrofdesustIrosnestneibmA edisroodtuofoerutarepmetgn
Suction sensor 
Its used for detecting suction pipe temperature of compressor to 
adjust gas flowing 
1
Defrosting sensor  Its used for controlling outdoor defrosting at heating mode  1 
taeh-revofoesacnirosserpmocrofdesustIrosnesgnigrahcseD
 
Conversation formulae 
Kcal/h= KW×860 
Btu/h= KW×3414 
cfm=m³/min×35.3 
30(double) 20(single)
Liquid-gas pipe 
 
sensor
Its used for adjusting the valve opening of the electric expansion    
2 
valve.