5.6 Electric characteristics
Units Power supply Indoor fan motor Power input (w)
Model Phase FQY Voltage
Volt.
range
MCA MFA
Output
(W)
FLA Cooling Heating
AB052MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 17 17
AB072MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 17 17
AB092MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 17 17
AB122MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 18 18
AB162MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 26 26
AB182MCERA(M) 1 50/60 220 198~242 0.325 1.04 26 0.26 35 35
Symbols:
MCA: Min. circuit amps (A)
MFA: Max. fuse amps of circuit breaker
Output: Fan motor rated output (w)
FLA: Full load amps (A)
Note:
1. Voltage range
The units are applicable for the electrical systems where voltage supplied to unit is in the range.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA=1.25*FLA MFA≤4*FLA
4. Power supply uses the circuit breaker.