EasyManua.ls Logo

Haier AC142ACNAC - Fault Codes; Diagnostic Information(Trouble Shooting)

Haier AC142ACNAC
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Code
Flash time of
compressor
running indicate
lamp
Trouble contents (new)
1 E0 10 drainage system trouble
2 E1 1 indoor temperature sensor broken
3 E2 2 indoor coil temperature sensor broken
4 E3 3 outdoor temperature sensor broken
5 E4 4 outdoor coil temperature sensor broken
6 E5 5 over current protect limit
7 E6 6 pressure protect
8 E7 7 three phase protect
9 E8 8
Communication trouble between wired remote controller
and indoor unit
10 E9 9 communication trouble between indoor and outdoor unit
Indicate lamp of remote control receiver board:
Green----power lamp
Yellow----timer lamp
Red----running of compressor
Red----water pump
The faults are shown by lamp flashing or display on the remote controller
10 DIAGNOSTIC INFORMATION (TROUBLE SHOOTING)
10.1 Fault codes
DIAGNOSTIC INFORMATION (TROUBLE SHOOTING)