5
1. Applicable ambient temperature range:
The machine is adaptive in following situation
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
    or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of  T 3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided.
    The connecting cable should be H05RN-F 4G 0.75mm
2
.
    All the cables shall have got the European authentication certificate. During installa-
    tion, when the connecting cables break off, it must be assured that the grouding wire is
    the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its
    two contacts should be no less 3mm.
7. The indoor unit installation height is at least 2.5m.
Safety Precautions
outdoor ambient temp.
operation mode
recommended fan speed
> 40¡
< 20¡
< -5¡
> 18¡
cooling
cooling
heating
heating
low
high
low
high
8. In order to obtain the Unit's best performances, the fan speed  is recommended according
    to the following conditions.
Rated Maximum Minimum
  27          32               18
  19          23               14
  35          43               10
  24          26                 6
  20          27               15
 14.5        --                 --
   7             24                -7
   6             18                 --
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
  27           32             18
  19           23             14
  35           43              -5
  24           26              --
  20           27              15
 14.5         --                --
   7            24              -7
   6            18              --