Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by outdoor unit.
Outdoor 3 phase type
Outdoor unit
terminal block
Indoor unit
terminal block
Power supply:1PH,220-240V~,50/60Hz
Y/G
1 2 3
Y/G
1 2 3
L N
Outdoor unit
terminal block
Indoor unit
terminal block
Power supply:380-415V, 3N~,50/60Hz
Y/G
1 2 3
Y/G
1 2 3
R S T N
Outdoor single phase type
Outdoor unit
terminal block
Indoor unit
terminal block
Power supply:1PH,220-240V~,50/60Hz
Y/G
1 2 3
Y/G
1 2 3
L N
Electrical wiring
Installation Procedure
25
Except ADH071M3ERG
ADH071M3ERG
Note:When do the wired controller & indoor PCB wiring work for model ADH071M3ERG,do not connect the shielded wired
to the unit's shell,do not parallel wiring with strong electric lines within 0.3 meters, please keep strong lines and the signal
lines separately.
WIRED CONTROLLER& INDOOR PCB CONNECTION(one for one wiring type):
A
B
C
.
INDOOR UNIT PCB
CN22
WIRED
CONTROLLER
CON1
A
B
C