EasyManua.ls Logo

Haier AFD631

Haier AFD631
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTROL AND DISPLAY SYSTEM
5.2.3 Malfunction display
Malfunction display and meaning
NO Items
Malfunction
display
Meaning
1 Normal
Display the
temperature
setting
No
2
Freezer storage
temperature sensor
malfunction
F2 F SNR short- or open-circuit
3
Ambient temperature
sensor malfunction
F3
RT SNR short- or open-circuit
4
Fridge storage
temperature sensor
malfunction
F1
R1 SNR short- or open-circuit
5
Defrosting temperature
sensor malfunction
F5
D SNR short- or open-circuit
6 Freezer fan malfunction E1 No signal for more than 30s
7
Communication
malfunction
E0
No communication between
the display panel and the
power board for 2 minutes

Related product manuals