Sensors list
Domestic air conditioner
TECHNICAL SPECIFICATIONS-PARTS
cooling heating
Fan
nafwolfssorCepyT
0404WtuptuorotoM
Air flow rate(high) m³/h 9000 900
Speed(super/high/low) rpm 1180/1000/800 1100/ 950/ 750
Heat exchanger
Type ML fin- 7HI-HX tube
4.1*41*3hctif*egats*tnemgeS
hgiRlortnocnoitceridriA t,Left,Horizontal,Downward
Air filter
Removable/Washable/Mildew Proof
Temperature control
Microcomputer Control
ledomrellortnocetomeR
Note: the data are based on the conditions shown in the table below
htgnelgnipiPgnitaehgnilooc
Indoor: 27 DB/19 WB
Outdoor: 35 DB/24 WB
Indoor:20 DB
Outdoor: 7 DB/6 WB
7m
4 Sensors list
type Description Qty
1erutarepmetmoorgnitcetedrofdesustIrosnesmooR
Pipe sensor Its used for detecting temperature of evaporator 1
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3