Installations
Domestic air conditioner
30
10.3.3
Indoor fan motor malfunction
Indoor Display
E14
Method of  
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation
Detection
Malfunction
when the detected rotation feedback signal don’t received in 2 minutes
Decision     
Conditions
Supposed Causes
Operation halt due to breaking of wire inside the fan motor.
Operation halt due to breaking of the fan motor lead wires.
Detection error due to faulty indoor unit PCB.
How to check Fan Motor (DC)
1. Check connector connection.
2. Check motor power supply voltage output (pins 1-4).
3. Check motor control voltage (pins 4-5).
4. Check rotation command voltage output (pins 4-6).
5.
Check rotation pulse input (pins 4-7).
Notes: the a/c is electrifying, don’t pull out or insert the terminals of the
motor, else the motor would be damaged.
Troubleshooting   
* Caution
Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
10.3.4 Outdoor DC fan motor fault 
Outdoor display  LED1    flash    9    times 
Method of  DC fan motor is detected by checking the fan running condition and so on 
Malfunction 
Detection 
Malfunction  when the data of EEPROM    is error or    the EEPROM    is damaged 
Decision 
Conditions 
Supposed  ■ DC fan motor protection dues to the DC fan motor fault
y
Causes 
■ DC fan motor protection dues t
o faulty PCB
Troubleshooting  * Caution    Be sure to turn off power switch before connect or disconnect connector,      or parts damag
may be occurred.