When connecting the cable after installing the indoor unit
Check Items for Test Run
When connecting the cable before installing the indoor unit
Cutting and Flaring Work of Piping
Power Source Installation
1.Insert from outside the room cable into left side of the wall hole,
in which the pipe has already existed.
2.Pull out the cable on the front side, and connect the cable
making a loop.
●Please install the drain hose so as to be downward slope without
fail.
●Please don’t do the drainage as shown below
●Insert the cable from the back side of the unit, then pull it out on
the front side.
●Loosen the screws and insert the cable ends fully into terminal
block, then tighten the screws.
●Pull the cable slightly to make sure the cables have been properly
inserted and tightened.
●After the cable connection, never fail to fasten the connected
cable with the wiring cover
Note:
When connecting the cable, conrm the terminal number of indoor
and outdoor units carefully. If wiring is not correct, proper operation
cannot be carried out and will cause defect.
Connecting wiring 4G1.0mm²
1.If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similar qualied person. The
type of connecting wire is H07RN-F.
2.If the fuse on PC board is broken please change it with the type
of T.3.15A/250VAC (Indoor).
3.The wiring method should be in line with the local wiring
standard.
4.After installation, the power plug should be easily reached.
5.A breaker should be incorporated into xed wiring. The breaker
should be all-pole switch and the distance between its two contacts
should be not less than 3mm.
●Please kindly explain to our customers how to operate through
the instruction manual.
□
Put check mark
in boxes.
●Please pour water in the drain pan of the indoor unit, and conrm
that drainage is carried out surely to outdoor.
●In case that the attached drain hose is in a room, please apply
heat insulation to it without fail.
●The power source must be exclusively used for air conditioner.
●In the case of installing an air conditioner in a moist place, please
install an earth leakage breaker.
●For installation in other places, use a circuit breaker as far as
possible.
●Pipe cutting is carried out with a pipe cutter and burs must be
removed.
● After inserting the are nut, aring work is carried out.
Flare tool Conventional are tool
Clutch-type clutch-type (Rigid-type)
Wing-nut type
(Imperial-type)
A 0~0.5 mm 1.0~1.5 mm 1.5~2.0 mm
Flare tooling die
1. Cut pipe
3. Insert the are nut
4. Flare pipe
2. Remove burs
Check for Installation and Test Run
On Drainage
On Drainage
Correct Incorrect
Lean
Damage of are
Crack Partial Too outside
It becomes high
midway.
The end is
immersed in
water
It waves.
The gap with
the ground is
too small.
Less
than
5cm
There is the
bad smell from
a ditch
Code
indication
Trouble description Analyze and diagnose
E1
Room temperature sensor
failure
Faulty connector connection;
Faulty thermistor;
Faulty PCB;
E2 Heat-exchange sensor failure
E4 Indoor EEPROM error
Faulty EEPROM data;
Faulty EEPROM ;
Faulty PCB
E7
Communication fault between
indoor and outdoor units
Indoor unit- outdoor unit signal transm ission error
due to wiring error
Faulty PCB;
E14 Indoor fan motor malfunction
Operation halt due to breaking of w ire inside the
fan motor;
Operation halt due to breaking of the fan motor
lead wires;
Detection error due to faulty indoor unit PCB;
□Gas leak from pipe connecting?
□Heat insulation of pipe connecting?
□Are the connecting wirings of indoor and outdoor rmly inserted
to the terminal block?
□Is the connecting wiring of indoor and outdoor rmly xed?
□Is drainage securely carried out?
□Is the earth line securely connected?
□Is the indoor unit securely xed?
□Is power source voltage abided by the code?
□Is there any noise?
□Is the lamp normally lighting?
□Are cooling and heating (when in heat pump) performed
normally?
□Is the operation of room temperature regulator normal?
5
6
7
8
9
Indoor unit
To Outdoor unit