EasyManua.ls Logo

Haier AS35RHBHRA - Page 32

Haier AS35RHBHRA
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Diagnosis
Replace the indoor or outdoor mainboard.
10.4.2 EEPROM abnormal
Indoor Display
Indoor display
E4: Indoor EEPROM error
F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times
The Data detected by the EEPROM are used to determine MCU
When the data of EEPROM is error or the EEPROM is damaged
Faulty EEPROM data
Faulty EEPROM
Faulty PCB
* Caution
:
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Method of
Malfunction
Detection
Malfunction
Decision
Conditions
Trouble
shooting
Supposed
Causes
30