WARNING
!
Ductless Split Air Conditioner
Indoor
AW09ES2VHA
AW12ES2VHA
AW18ES2VHA
AW24ES2VHA
AW07LC2VHA/AW07LC2VHB
AW09LC2VHA/AW09LC2VHB
AW12LC2VHA/AW12LC2VHB
AW18LC2VHA/AW18LC2VHB
User Manual
Design may vary by model number.
ŢThis system should be installed by a
HVAC professional. Do not attempt to install
the air conditioner by yourself because
incorrect installation may cause
water
leakage, personal injury or death.
Ţ When abnormalities such as a burnt-smell are
found, immediately power
the main switch
and contact a licensed contractor.
Ţ Do not obstruct or cover the ventilation grille
on the air conditioner. Do not put
or
any other things into the inlet/outlet or swing
louver.
Ţ Do not allow children to play with the air
conditioner. Children should never be allowed
to sit on the outdoor unit
Ţ Please read this manual before using the air conditioner.
Ţ Keep this user manual for future reference.
Cautions and Warnings ................................. 1
Controller Features & Settings ...................... 2
Emergency Operation & Maintenance ........... 5
Troubleshooting ............................................ 6
Limited Warranty .......................................... 7
TABLE OF CONTENTS
PAGE 1
0010586611

Other manuals for Haier AW09LC2VHB

Questions and Answers

Summary

Cautions and Warnings

General Safety Warnings

Crucial safety instructions for installation and operation to prevent fire, injury, or death.

Controller Features & Settings

Remote Controller Overview

Explanation of the remote controller's buttons, modes, and display icons for operation.

Air Flow Direction Adjustment

How to adjust vertical and horizontal airflow louvers for optimal air distribution.

Timer Functions

Setting the timer to automatically turn the unit ON or OFF at desired times.

Sleep Mode Operation

Utilizing the sleep mode to automatically adjust temperature for comfort during rest.

Extra Function Button

Accessing advanced features like intelligent airflow and unit settings.

Emergency Operation & Maintenance

Emergency Operation Mode

How to operate the unit manually when the remote control is defective or lost.

Inserting Remote Batteries

Instructions for installing and replacing batteries in the remote control unit.

Optimizing Performance

Tips for efficient operation, including closing doors and avoiding obstructions.

Cleaning the Air Filter

Step-by-step guide on how to remove, clean, and reattach the air filter.

Troubleshooting

Before Asking for Service

Common problems, causes, and solutions to check before contacting a technician.

Limited Warranty Information

Warranty Coverage Details

Information on parts, compressor warranty, and what is not covered by the warranty.

Summary

Cautions and Warnings

General Safety Warnings

Crucial safety instructions for installation and operation to prevent fire, injury, or death.

Controller Features & Settings

Remote Controller Overview

Explanation of the remote controller's buttons, modes, and display icons for operation.

Air Flow Direction Adjustment

How to adjust vertical and horizontal airflow louvers for optimal air distribution.

Timer Functions

Setting the timer to automatically turn the unit ON or OFF at desired times.

Sleep Mode Operation

Utilizing the sleep mode to automatically adjust temperature for comfort during rest.

Extra Function Button

Accessing advanced features like intelligent airflow and unit settings.

Emergency Operation & Maintenance

Emergency Operation Mode

How to operate the unit manually when the remote control is defective or lost.

Inserting Remote Batteries

Instructions for installing and replacing batteries in the remote control unit.

Optimizing Performance

Tips for efficient operation, including closing doors and avoiding obstructions.

Cleaning the Air Filter

Step-by-step guide on how to remove, clean, and reattach the air filter.

Troubleshooting

Before Asking for Service

Common problems, causes, and solutions to check before contacting a technician.

Limited Warranty Information

Warranty Coverage Details

Information on parts, compressor warranty, and what is not covered by the warranty.

Overview

The Haier Ductless Split Air Conditioner is a user-friendly system designed for efficient cooling and heating, offering various models for different indoor needs. The indoor units include AW09ES2VHA, AW12ES2VHA, AW18ES2VHA, AW24ES2VHA, AW07LC2VHA/AW07LC2VHB, AW09LC2VHA/AW09LC2VHB, AW12LC2VHA/AW12LC2VHB, and AW18LC2VHA/AW18LC2VHB.

Function Description:

This ductless split air conditioner provides cooling, heating, and dehumidification functions. It is operated via a remote control, allowing users to select various modes and settings for optimal comfort. The system is designed to be installed by a qualified HVAC professional to ensure correct setup and prevent potential hazards.

Important Technical Specifications:

  • Operating Temperature Range: 60°F-86°F (16°C-30°C).
  • Fan Speeds: Low, Medium, High, and Auto.
  • Timer Functions: TIMER ON and TIMER OFF, allowing scheduled operation in 0.5-hour increments up to 12 hours, and 1-hour increments between 12 and 24 hours.
  • Sleep Mode: Automatically adjusts temperature and fan speed for comfortable sleep, with a total run time of approximately 6 hours in cooling/dry modes and 3-6 hours in heat mode before turning off.
  • Power Supply: The manual does not specify voltage or current, but mentions checking for power plug insertion, power failure, and blown fuses during troubleshooting.
  • Refrigerant: The manual mentions "refrigerant flowing in the system" in the context of noise, implying a standard refrigerant-based cooling cycle.

Usage Features:

  • Remote Control: The primary interface for controlling the air conditioner. It features buttons for Power, TURBO/QUIET, COOL, HEAT, DRY, Temperature +/- (Temp+ / Temp-), AUTO, FAN, Swing (vertical and horizontal louvers), Health, Timer On, Timer Off, Extra Function, Sleep, Confirm/Cancel, Lock, Light, and Reset.
  • Power Button: Turns the unit ON/OFF.
  • TURBO/QUIET Button:
    • TURBO Function: Provides fast heating or cooling. Pressing the button once activates TURBO mode, indicated by a "J" icon on the remote display.
    • QUIET Function: Reduces noise for quiet operation. Pressing the button a second time activates QUIET mode, indicated by an icon on the remote display. Running in QUIET mode for extended periods may affect temperature attainment.
    • Pressing the button a third time cancels TURBO/QUIET mode.
  • COOL Button: Activates cooling mode. When FAN is set to AUTO, the unit automatically adjusts fan speed based on room temperature.
  • HEAT Button: Activates heating mode. Features a cold-air prevention function. When FAN is set to AUTO, the unit automatically adjusts fan speed.
  • DRY Button: Reduces humidity. Operates intermittently at LOW speed when room temperature is within 2°F of the set temperature.
  • Temperature +/- Buttons: Adjusts the set temperature within the 60°F-86°F (16°C-30°C) range.
  • AUTO Button: Automatically selects Cool, Heat, or Fan operation based on the set temperature. Fan speed is automatically adjusted in AUTO mode.
  • FAN Button: Cycles through fan speeds: LOW, MED, HI, and AUTO.
  • Louver SWING Buttons (Vertical and Horizontal): Adjusts the direction of airflow. The vertical louvers can be adjusted using the SWING UP/DOWN button. The horizontal louvers can be adjusted using the SWING UP/DOWN button (for horizontal swing).
    • Caution: Avoid keeping vertical louvers in the downward position in COOL or DRY mode to prevent condensate water formation. Avoid adjusting horizontal louvers manually to prevent malfunction.
  • Timer ON/OFF Buttons:
    • TIMER ON: Schedules the unit to turn on after a set period.
    • TIMER OFF: Schedules the unit to turn off after a set period.
    • Settings are confirmed using the CONFIRM/CANCEL button.
  • SLEEP Button: Activates sleep mode, which automatically adjusts temperature and fan speed for comfort during sleep. Fan speed is fixed to low in sleep mode.
  • EXTRA FUNCTION Button: Provides access to additional settings:
    • A-B Yard: Allows control of two separate units with one remote (requires contractor setup).
    • Fan Mode: Activates fan-only operation.
    • Intelligent Airflow (Upward/Downward/Reset): Adjusts louver position for specific airflow patterns (e.g., upward for cooling, downward for heating).
    • Fahrenheit/Celsius Mode Shift: Switches temperature display between °F and °C.
  • LOCK Button: Locks the remote control buttons and LCD display.
  • LIGHT Button: Turns the indoor unit's display ON/OFF.
  • RESET Button: Resets the remote control using a pen point or similar object.
  • Emergency Operation: If the remote control is defective or lost, the unit can be operated via an emergency switch. In this mode, the unit runs automatically (COOL above 73°F, HEAT below 73°F) with fixed temperature and fan speed settings, and timer/dry modes are unavailable.

Maintenance Features:

  • Cleaning the Air Filter:
    1. Open the inlet grille by pulling it upward.
    2. Remove the filter by gently pushing up on its center tab and pulling it downward.
    3. Clean the filter using a vacuum cleaner or by washing with water. Ensure the filter is completely dry before reattaching.
    4. Attach the filter with the "FRONT" label facing forward, ensuring it's securely attached behind the holding tabs.
    5. Close the inlet grille.
    • Recommendation: Clean the air filter every two months for optimal efficiency.
  • General Cleaning: Wipe the air conditioner with a soft, dry cloth. For serious stains, use a neutral detergent diluted with water, wringing the cloth thoroughly before wiping.
  • Battery Replacement: The remote control uses 2 AAA batteries. Replace them when the display is weak or operating distance diminishes. Remove batteries if the unit will not be used for an extended period.

Safety and Installation Warnings:

  • Installation must be performed by a qualified HVAC professional to prevent fire, water leakage, personal injury, or death.
  • Immediately power off the main switch and contact a licensed contractor if abnormalities (e.g., burnt smell) are detected.
  • Do not obstruct or cover the ventilation grille.
  • Do not insert fingers or objects into the inlet/outlet or swing louver.
  • Do not allow children to play with the air conditioner or sit on the outdoor unit.
  • Read the user manual before use and keep it for future reference.

Troubleshooting:

The manual provides a troubleshooting guide for common issues:

  • System does not restart immediately: A 3-minute protection delay after stopping or power disconnection.
  • Noise is heard: Swishing/gurgling noise from refrigerant flow, cracking noise from casing expansion/contraction, or loud airflow due to a dirty air filter.
  • Odd smell: System circulates smells from indoor air (furniture, paint, cigarettes).
  • Mist or steam blowing out: Due to sudden cooling of indoor air in COOL or DRY mode.
  • Fan speed can't be changed in dry mode: Unit runs intermittently at LOW speed when room temperature is near set temperature.
  • Poor cooling: Check power plug, power failure, fuse, dirty air filter, blocked inlet/outlet, incorrect temperature setting, open doors/windows, direct sunlight, or too many heat sources/people in the room.

Haier AW09LC2VHB Specifications