6
Electrical Schematic
Note: The allowable error range
of the above parameters
(weights) is ±10%.
Technology Datas
F1 Serie
1 1 4 1 2
TF7 Serie
/
Expansion
Bolt
(unit)
Model
Quantity
Name
Packing List
Electric Water
Heater
(unit)
Expansion
hook
(unit)
Wall-mounting
frame
(unit)
Safety Valve
(unit)
Instruction
Manual
(unit)
1 1 / 1 / 2
ES50V-F1(EU) 3000W
3000W
3000W
25kg
34kg
41kg
47L
74L
97L
ES80V-TF7(EU)
ES100V-F1(EU)
ES50V-TF7(EU)
3000W
25kg
46L
ES80V-F1(EU)
3000W
33kg
77L
Rated Power
Net Weight
Rated CapacityModel
220-240
V~
50
Hz
0.80
MPa
75°C IPX4
Waterproof LevelRated Voltage
Rated
Temperature
Rated Frequency Rated Pressure
All models
1500W 18kg
47L
ES50V-VH3(EU)
1500W 13kg
28L
ES30V-VH3(EU)
1500W 30kg
95L
ES100V-VH3(EU)
1500W 26kg
75L
ES80V-VH3(EU)
F1 Serie
Display Board
MT2
RT1
L
N
PE
EH
PE
RT2
MT1
N
Relay
Relay
VH3 Serie
T2
EH
RT1
MT1 MT2
E
L
N
E
Display Board
Relay
Relay Relay
L - Live wire (brown)
N - Neutral wire (blue)
PE/E - Ground wire (yellow and green)
MT/MT1/MT2 - Manual reset thermostat
EH - Heating tube
RT/RT1/RT2 - Sensor
Relay
Display panel
L
N
E
MT
N
EH
E
RT
TF7 Serie