Installation
Fresh water connection
WARNING!
It is recommended to have the appliance installed by a qualied technician .
Make sure that the mains plug is disconnected from the mains socket .
Make sure the water supply is blocked .
A shut - o valve which must be easy accessible after installation must be in-
stalled between the hose and the domestic water connection in order to be able
to interrupt the water supply if necessary .
Only connect to cold water supply .
Use only the supplied hose set for the connection .
Only connect to drinking water supply. The water lter only lters impurities in
the water and makes ice clean and hygienic . It cannot sterilize or destroy germs
or other harmful substances .
Too high water pressure in the hose can damage the appliance . Install a pres-
sure reducer when the water pressure in the hose exceeds 0.6 MPa .
Before connection , check whether the water is clean and clear .
NOTICE:Water connection
Pressure of the cold water has to be 0.15-0.6 MPa .
The maximum permitted length of water hose is 8 meter . Longer hoses will af-
fect the ice cubes and cold water content .
Ambient temperature has to be 0°C minimum .
Keep the water hose away from heat sources .
Follow the installation instructions below:
Fig.1
36
Fig.2
Fig.3
1.Cut the pipe into two pieces with the required
length to connect the lter ( A ) with the appli-
ance (B1) and the water tap (B2)( Fig .1). Make
sure to get a square cut by using a sharp knife .
2.Insert pipe (B1) approx .12 mm deep into
the mounting xture of the water ter ( A )( Fig
.2). Take care to install the ter in the correct
direction . The dart shows the direction of water
ow .
3. Secure the pipe with a locking clip ( C ) ac-
cording to Fig .3.