of a problem please check all shown possibilities and follow below instructions before y
contact an after sales service. See CUSTOMER SERVICE.
Error Code Cause Solution
L2
H1
WARNING!
Before maintenance, deactivate the appliance and disconnect the mains plug from
the mains socket.
improper repairs can cause considerable consequential damages.
A damaged supply should only be replaced by the manufacturer, its service agent or
Low temperature alarm when the
temperature of the control sensor
is too low;
When the temperature of the con-
trol sensor is too high, the high te-
mperature alarm will be displayed
on the display screen;
1.Check the connector of the cont-
rol board or the display panel.
2.Check the resistance and the vol-
tage of the fan.
3.Check the fan and the compres-
sor connector.
1.Check the ambient temperature .
2.Check the Compressor connec-
tor.
3.Check the resistance of the tem-
perature control sensor.