Instruction of replacing sensor 
Step  Tools  Operation content  Pic I  Pic II 
1.remove fault 
part
scissors
Open up sensor cover, nip 
connection thread of which near to 
sensor root place.   
2.poke
insulation skin   
knives
Cut off insulation skin orderly till 
appearing two thread with length of 
10mm, new sensor head also cut off 
10mm,and make sure connection 
thread 25mm around. 
3.repair 
connection 
port
knives ,
electric
iron
Cut off isolation skin about 2-3mm 
of 10mm two thread, and with 
electric iron plating soldering tin(4 
connection port ).   
4.connection  
electric
iron ,pyr
oconde
nsation 
pipe  
Make pyrocondensation tube cover 
the two thread, and with electric iron 
jointing two ports (old sensor port 
and new sensor port), pay attention 
to not causing burr.   
5.seal
electric
iron,
seal
glue  
After jointing together, make 
pyrocondensation located 
connection jointing point middle 
part, heat up pyrocondensation pipe 
in order to make it shrinkage and 
cover jointing point firmly, and 
dripping seal glue in order to wet 
corrupt.
6.install  
Install sensor to sensor cover, then 
fix it up. 
 
TROUBLESHOOTING
Instruction of replacing sensor