Non-volatile Memory
1. Under on state and backlight is on, press function key 10
times in 5 seconds. The non-volatile memory function is set
after buzzer sounds 4 times. After this setting, on/o󰀨 state,
running mode, fan speed, set temperature, swing, electrical
heating state, health and fresh are memorized in program.
After power failure, all above modes are kept in same state
as that before power failure. Press function key 10 times in
5 seconds to cancel the non-volatile memory function. The
buzzer will sound 2 times. After you cancel this function,
once power failure happens, the wired controller is o󰀨 state
after power comes back. The running mode is intelligent
mode, auto fan speed, 24°C. If you set non-volatile memory
and timer or sleeping function, the wired controller enters
o󰀨 state after power failure, then enters the previous state.
Matching Central Controller/130
The controller displays when the indoor unit send lock
signal (state, not command) to controller. All keys are invalid
including remote control signals.
2. Keep pressing fan speed key and function keys for 5s
together to set or cancel child lock, this setting way can
execute the same function to the other way that pressing
function key 12 times or 4 times in 5s to set or cancel child
lock.