To ensure continued safe and efficient operation of the appliance
it is recommended that it is checked and serviced as necessary at
regular intervals. The frequency of servicing will depend upon the
• particular installation conditions and usage but in general once a
year should be adequate. It is the law that any service work
MUST be carried out by a registered engineer such as British Gas
or CORGI registered personnel.
. , IGNITION LOCK -OUT
In the event of an ignition failure, the red safety Lockout LED will be
illuminated. Turn the main switch through to the Reset position and
release (spring return to setting).
, OVERHEAT THERMOSTAT
This appliance is fitted with an overheat thermostat. In the event of
overheating, the appliance will shut down and the red safety
Lockout lED will light. If an overheat condition occurs allow the
appliance to cool, then press the overheat reset button once. It is
located underneath the appliance at the ~eh hand side, the ignition
I
=
Con~nuous ON
C9
0= Timed
TABS OUT
=
ON
PERIOD
TABS IN
=
OFF
PERIOD
will also require re-setting before the ignition sequence can take
place. If this fault condition is repeated, contact your installer or
service engineer.
This appliance is fitted with a frost protection device. In the event
of very cold conditions the pump may operate and the boiler may
light for a few minutes to protect the appliance and system from
potential frost damage. This can only function if the gas and
electricity supplies are maintained and the main switch on the
appliance is leh in the hot water or heating and water mode. The
clock can be switched to the off setting .
-: PRESSUREGAUGE
The pressure gauge on the fascia panel indicates the approximate
system pressure. If the normal running pressure is seen to decrease
over a period of time there is a water leak. Consult your installer
or service engineer.
~. ELEGRICAL SUPPLY
This appliance requires a 230V
N50Hz
electrical supply fused at
3A.
THIS APPLIANCE MUST BE EARTHED.