EasyManua.ls Logo

Hanna HI 5522 User Manual

Hanna HI 5522
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HI 5521 & HI 5522
pH/mV/ISE/Temperature/
Conductivity/Resistivity/TDS/Salinity
Bench Meters
Instruction Manual
www. .com
information@itm.com1.800.561.8187
Question and Answer IconNeed help?

Do you have a question about the Hanna HI 5522 and is the answer not in the manual?

Hanna HI 5522 Specifications

General IconGeneral
ModelHI5522
ORP Resolution0.1 mV
ORP Accuracy±0.2 mV
Temperature Range-20.0 to 120.0 °C (-4.0 to 248.0 °F)
ConnectivityUSB
GLPYes
TypepH/ORP Benchtop Meter
pH Range-2.0 to 20.0 pH
pH Resolution0.01 pH
ORP Range±2000 mV
Temperature Resolution0.1 °C; 0.1 °F
Temperature Accuracy±0.2 °C; ±0.4 °F
CalibrationUp to five-point calibration
DisplayGraphic LCD
Power Supply12 VDC adapter

Summary

General Description

Functional Description

Specifications

Operational Guide

Electrode and Probe Connections

Details how to connect pH, ORP, ISE electrodes and conductivity probes.

Instrument Start Up

System Setup

Restore Factory Settings

Resets the instrument to default factory settings.

Software Update

Procedure for updating the instrument's software.

pH Setup

Calibration Setup

Configure buffer entry type, 1st calibration point, and custom buffers.

pH CALIBRATION

Calibration Procedure

Step-by-step guide for calibrating the pH electrode.

pH MEASUREMENT

mV & Relative mV MEASUREMENTS

mV/ORP Measurements

Explains ORP measurements and electrode care.

Direct Measurement (mV)

How to measure mV in Direct mode.

Direct/AutoHold Measurement (mV)

How to measure mV using Direct/AutoHold mode.

EC PROBE USE AND MAINTENANCE

pH PROBE MAINTENANCE

pH Cleaning Procedure

Specific cleaning solutions for pH electrodes.

TROUBLESHOOTING GUIDE

mV/pH/ISE Channel Symptoms

Troubleshooting common issues for mV, pH, and ISE measurements.

Conductivity/Resistivity/TDS/Salinity Channel Symptoms

Troubleshooting common issues for conductivity-related measurements.

CONDUCTIVITY SETUP

Profile Management

Save, load, or delete measurement profiles for conductivity setup.

CONDUCTIVITY CALIBRATION

Offset Calibration

Calibrates the probe's offset value.

Cell Constant Calibration (in solution)

Calibrating the cell constant using standard solutions.

Cell Constant Calibration (edited by the user)

Manually setting the probe's cell constant value.

Cell Constant

Calibrate or edit the conductivity probe's cell constant.

LOGGING

Logging Type Selection

Choose between Automatic, Manual, and Auto Hold logging types.

Alarm Settings

RESISTIVITY SETUP

TDS SETUP

SALINITY SETUP

CONDUCTIVITY MEASUREMENT

USP EVALUATION

Stage 1: In-line Test

Performing the initial in-line USP test for water quality.

Stage 2: Off-line Test

Performing the second off-line USP test.

RESISTIVITY MEASUREMENT

TDS MEASUREMENT

Direct Measurement

How to measure TDS in Direct mode.

Direct/AutoHold Measurement

How to measure TDS using Direct/AutoHold mode.

SALINITY CALIBRATION

SALINITY MEASUREMENT

TEMPERATURE CALIBRATION

PC INTERFACE

ISE THEORY

Related product manuals