10. Addendum
Schematic diagram for air conditioning
(The specific technical parameters of the machine shall be subject to the
nameplate on the product)
Condens
Compress
Evaporat
Capillary
Treatment: Don’t put the abandoned machine with other unsorted waste
together.
10474164 10474166
Description Symbol Unit Value Value
Rated cooling eciency P rated c kW 2,64 2.64
Rated heating eciency P rated kW - -
Rated power consumption for cooling P EER kW 1,01 1.01
Rated power consumption for
heating
P EER kW - -
Energy Eciency Index for Cooling
EERd - 2,60 2.60
Energy Eciency Index for heating
COPd - - -
Power consumption in o -mode
thermostat
P TO W - -
Power consumption in standby
mode
P SB W 1 1
Electrical energy consumption of
air conditioners -single channel
-two -channel (cooling)
SD: Q SD
DD: Q DD
SD: kWh/h
DD: kWh/a
1,01
-
1,01
-
Sound power level
L WA dB (A) 65 65
Global warming Potential
GWP kg CO2 3 3