Parameter
Nonimal
Specification
Unit
QA Test
Limits
Conditions
Notes
Amp Sectio
n
ATO Turn-OFF Time 12 minutes
5 - 17
Time before muting, after signal is
removed
Power on Delay tim
e
3 sec.
functional
AC Power Applied
Transients/Pop
s
ATO Transient 5 mV-peak
10
@ Speaker Outputs
Turn-on Transient 500 mV-peak
700
@ Speaker Outputs
A
C Line cycled from OFF to O
N
Turn-off Transient 500 mV-peak
700
@ Speaker Outputs
A
C Line cycled from ON to OF
F
Efficienc
y
Stand-by Input Power 8 Watts
12
@ nom. line voltage
Maximum allowable input power
under nominal input voltage and
frequency, in stand-by mode (HOT
or COLD operation).
Power Consumption @ rated power 240 Watts
250
@ nom. line voltage
200 Watts @ 3.5 ohms and
nominal line voltage
Protectio
n
Short Circuit Protection YES
functional
Direct short at output
A
mplifier should resume operation
after short circuit condition is
removed.
Thermal Protection YES
functional
Any user accessible metal parts
should always remain at 65 degree
C or less for domestic version or 5
5
degree C or less for EU version.
DC Offset Protection YES
functional
DC present at Speaker Out leads
Relay or crowbar (for driver/fir
e
protection),
Primary Fuse Rating
USA-Domestic 3.15 Amps
n/a
Type-T or Slo Blo (no DENTORI
User-replacable fuse with
UL/SEMCO rated holder.
3
SUB-TS18 harman/kardon

Other manuals for Harman Kardon SUB-TS18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman Kardon SUB-TS18 and is the answer not in the manual?

Harman Kardon SUB-TS18 Specifications

General IconGeneral
BrandHarman Kardon
ModelSUB-TS18
CategorySubwoofer
LanguageEnglish

Related product manuals