Read these instructions carefully before you attempt to install 
or operate the Advance. Failure to do so may result in dam-
age to property or personal injury and  may void the product 
warranty.
Consult with your local building code agency and insurance 
representative  before  you  begin  your  installation  to  ensure 
compliance with local codes, including the need for permits 
and follow-up inspections.
Several issues must be addressed when selecting a suitable 
location for your Advance Pellet Stove. Observing required 
clearances to combustible materials, the proximity to a safe 
chimney or venting system, and the accessibility of electrical 
supply must all be considered. In addition, selecting a location 
that takes advantage of the building's natural air ow is also 
desirable to maximize the heating effectiveness of the heater. 
In many cases, this is a central location within the building.
Place the stove on a noncombustible oor protector that ex-
tends 6 inches to the front, 6 inches to the sides and 1 inch 
to the rear of the stove. (Fig. 8.) 
Place the stove away from combustible walls at least as far 
as shown in gures 6, and 7. The clearance to a ceiling above 
the appliance is 24" (61cm).
Note that the clearances shown are  minimum for safety, but 
do not leave much room for access when cleaning or servicing. 
Please take this into account when placing the stove.
When installing this stove in a mobile home several require-
ments must be followed: 
1. The unit must be bolted to the oor. This can be done with 
1/4" lag screws through the 2 holes in   the base plate shown 
in Fig. 11, Page 10. 
2. The unit must also be connected to outside air. See page 14.
3. Floor protection and clearances must be followed as shown 
to right.
4. Unit must be grounded to the metal frame of the mobile 
home.
5. The unit may not be installed in a bedroom.
        
Installation  and  repair  of  this  stove  should  be  done  by  a 
qualied service person. The appliance should be inspected 
before use and at least annually by a qualied service person. 
Frequent cleaning will be required. It is imperative that control 
compartments, burners, and circulating air passageways of 
the stove be kept clean.
Fig.6
Fig.7
7"
7"
1"
10"
      6"
(152mm)
6" (152mm) 
Fig.8
FLOOR 
PROTECTOR
     6"
(152mm)
Floor protection measured from window opening.
1"