VENTING
Hole with a minimum clear-
anceoflS"
(450 mm)be-
tween connector
and
wall
Noncombustible cover, one
side only.
If
two covers
are
used, each must be mounted
on noncombustible spacers at
least
7/8"
(21
mm) away
from
thcwall.
1"(2Smm)
AN
APPROVED CANADIAN
WALL PASS-THROUGH
The Chimney
The Oakwood
must
be
installed into a chimney
approved for use with solid-fuel appliances. In the
U.S.,
the Oakwood must
be
connected to (1) a prefabricated
chimney complying
with
the requirements for Type
HT
chimneys in the Standard for Chimneys, Factory-Built,
Residential Type and Building Heating Appliances,
UL
103,
or
(2) a code-approved masonry chimney with a flue
liner.
In
Canada, the Oakwood is listed for use with pre-
fabricated chimneys
~ested
and listed to the ,high tem-
perature
(650 degrees C) chimney standard, ULC S-629,
or with a code approved masonry chimney.
The minimum recommended height for any chim-
ney is 16
ft
(4.8 m) above flue collar height.
For
non-
mobile home installations, a round flue (either masonry or
approved prefabricated),
of
either 6" (150 mm),
7"
(180
mm)
or
8"
(200 mm)
may
be
used.
For
square
or
rectan-
gular masonry chimneys, nominal sizes
of
8"
x
8"
or 8"x
12"
(200
mm
x 200 mm, 200
mm
x 300 mm) may
be
used.
Codes require that solid-fuel chimneys extend 3
ft
(0.9 m) above the point at which they exit
fromthe
roof,
provided that no part
of
any structure is within
the
top
of
the chimney, then the chimney
must
extend 2
ft
(6 m)
above the highest point with the 10
ft
(3
m) radius top
height.
If
there is hot ten feet
of
clearance from the top
of
the chimney, then the chimney must extend 2
ft
(6m)
above the highest point with the 10
ft
(3m) radius.
" -
~
-~
~~-
~
-
Minimum
12"
(300
mm)tocombustibles
Minimum2"
(SOmm)
Minimum
12"
Liner
(300mm) to brick
~
/FireClay
;;::
,.... .....
~
thimble
~
C:
___
i""o::"
.S
Chimney
t5
connector
MlnrYchimnev
builtto NFPA211
specifications
AN
APPROVED U.S.
WALL PASS-THROUGH
Do
not
connect this unit to a chimney flue
servicing another appliance.
NOTE: The restriction
of
not venting more than
one appliance to the same flue applies to the
U.S.
specifi-
cally. While
it
is not recommended that you use the same
chimney for more than one appliance, in
Canada certain
exceptions may
be
made.
Be
sure to contact your build-
ing code inspection official to see
if
this option is allowed
in your area, and to find out the specific requirements for
such an installation.
More
than 10ft
(3
m)
THE 2-FOOT, 3-FOOT, 10-FOOT RULE
Oakwood Wood Stove
17