8. Turn the MIN. TEMP. Dial on the control board
to the desired Minimum temperature. This will start the
lighting process if the temperature at the aquastat sensor
is approximately 5° F. less than the set temperature on the
MAX TEMP. dial.
This is more than just an automatic ignition pellet boiler.
The automatic system will allow the re size to be adjusted
to match the heating needs and even put the re out if
necessary. If heat is needed after the re is out, the boiler
will automatically re-ignite and adjust the re size to match
the heating need.
9. Fill hopper with pellets and remove ashes as required.
Type of Fuel
Use pelletized wood only. The lower the ash content of
the pellets the less cleaning that will be needed of the heat
exchanger surfaces. The cleaner these surfaces are kept, the
more efcient the boiler will be.
NOTE: Do not burn garbage, gasoline, naphtha, engine
oil, or other inappropriate materials in this unit.
Store pellets in the manufacturer’s wrapping until needed
to prevent pellets from absorbing moisture. Do not store
fuel within the appliance installation clearances, or within
the space required for fueling, ash removal, and other
routine maintenance operations.
Lighting A Fire Manually
Lighting the re manually will not be necessary unless the
igniter system fails.
Follow steps 1 through 5 of the instructions for automatic
lighting.
6. Flip the Igniter Switch Down into the “MANUAL-
LIGHT” position. See Fig. 12.
7. Open hopper swing plate as shown in Fig. 13 (See
“NOTE” on page 26.)
8. Fill burnpot with pellets as shown. See Fig. 14.
Only ll level with the front edge.
( ------- DO NOT OVERFILL ------- )
9. Have matches or other ignition source ready.
10. Turn Mode Selector to desired MIN TEMP setting.
This will start the combustion blower and allow the
ESP to control the re in relation to the MAX TEMP
Dial setting. (The MAX TEMP dial setting must always
be set above the MIN TEMP setting) Once the re is
well established the MAX TEMP dial can remain on
any temperature setting desired.
NOTE: When the Switch is set to Manual ignite
position the boiler will function as in auto ignite except the
re will not be allowed to go out. It will only be allowed to
go to a minimum burn rate between the times the aquastat
is calling for heat. This rate is about 1.1 pound of fuel per
hour. If used in the Manual ignite mode, be sure there is an
overheat dump zone in place. Note that if the dump zone does
not provide sufcient cooling, and the water temperature
continues rising, the feed motor will be forced to shut off.
Because the unit is in Manual Ignite mode, it will not re-ignite
when the water temperature cools below the control settings.